Servicezeiten: Montag bis Freitag 9:00-18:00
UHLC2CE - UHLC2CE HL-C2CE PANASONIC Control unite HL-C2, low resolution, -5 to +5V, 4-20mA, NPN-type
Vorrätig Top‑Produkt

UHLC2CE

UHLC2CE HL-C2CE PANASONIC Control unite HL-C2, low resolution, -5 to +5V, 4-20mA, NPN-type

$0.00USD
3104 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Gewicht:450 g approx.
Details:Controller
Produkt:Ultra High-speed High-precision Laser Displacement Sensor
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Gewicht450 g approx.
DetailsController
ProduktUltra High-speed High-precision Laser Displacement Sensor
MaterialCase: Polycarbonate
ZubehörUSB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc.
TeilenummerHL-C2CE
Reset-EingangReset is done when connected to Common (-).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
AlarmausgangNPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between alarm output and Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current)
ProduktnameUltra High-speed・High-precision Laser Displacement Sensor HL-C2
ZeiteingangON at/during connection to Common (-)(depending on analysis mode)Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Abtastrate10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Stroboskop-AusgangNPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between strobe output to Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current)
ProduktnummerHL-C2CE
Versorgungsspannung24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Null-EingangZero set is ON when connected with Common (-).Zero set turns to OFF after continuously connected to Common (-) for one second.Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Anzeige: LeistungGreen LED (lights up at power on)
Aktueller Verbrauch500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected)
Anzeige: Alarm 1Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Anzeige: Alarm 2Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Laser-SteuereingangLaser emission is stopped when connected to Common (-).Laser is emitted immediately after opened.Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
SpeicheränderungseingabeMemory is specified when connected to Common (-).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Connectale SensorkopfNumber of connectable units: Max. 2 units.
FernverriegelungseingangLaser emission is delayed when connected to Common (-).Laser emission stop at openApplied voltage: 30 V DC or less(Leak current: 0.1 mA or less)
Analogausgang: StromCurrent output scale: 4 to 20 mA/F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Analogausgang: SpannungVoltage output scale: -5 to +5 V/F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mV, Linearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Beurteilungsergebnis (HI, GO, LO)NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between judgment output to Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current)
Alarmausgang: AusgangsfunktionOpened when the amount of light is insufficient
Stroboskopausgang: AusgangsbetriebOpened at data determination
Alarmausgang: KurzschlussschutzIncorporated
Blitzlichtausgang: KurzschlussschutzIncorporated
Indikator: Sensorkopf A LaserstrahlungGreen LED (lights up during or immediately before laser emission of sensor head A)
Indikator: Sensorkopf B LaserstrahlungGreen LED (lights up during or immediately before laser emission of sensor head B)
Umweltbeständigkeit: Umgebungsfeuchtigkeit35 to 85 %RH
Umweltbeständigkeit: Stoßfestigkeit196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each
Umweltbeständigkeit: Umgebungstemperatur0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Entscheidungsergebnis (HI, GO, LO): AusgabeoperationOpened at output operation
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Ausgang (HI, GO, LO): KurzschlussschutzIncorporated

Produktbeschreibung

High performance analog laser low resolution controller, HL-C2 series, RS232 port, analog output ±5V/ 4 - 20mA, NPN digital output
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung