Wichtige Spezifikationen
:When communication unitis connected
Artikel:Specifications
Kabel:0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
Details:Master unit / High performance type
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
When communication unitis connected
ArtikelSpecifications
Kabel0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong
DetailsMaster unit / High performance type
ProduktController
MaterialCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Nettogewicht140 g approx.
TeilenummerHG-TC101-P
1 bis 7 Einheiten1 to 6 units
ProduktnameThru-beam Type Digital Displacement Sensor HG-T
8 bis 15 Einheiten7 to 14 units
Anzeigebereich-199.999 to 199.999 mm-7.874 to 7.874 in
Abtastrate1 ms (standard sampling) / 0.5 ms (high-speed sampling)
ProduktnummerHG-TC101-P
Versorgungsspannung24 V DC ±10 %, including ripple 0.5 V (P-P)
Verschmutzungsgrad2
Bildschirmauflösung1 μm0.039 mil
Betriebshöhe2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Aktueller Verbrauch100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output.
Einhaltung gesetzlicher BestimmungenCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Geeigneter SensorkopfHG-T1010、HG-T1110
Externe EingangsumschaltungInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
Externe AusgangsumschaltungOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
Durchschnittliche Anzahl (Reaktionszeit)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Anzahl der verbundenen Slave-EinheitenMaximum sink current and sourcecurrent of control output
StörungsverhinderungsfunktionIncorporated(Note) : This function operates for each set of 4 connected controllers.
Umweltbeständigkeit: SchutzIP40(IEC)
Analogausgang: Analoger Stromausgang•Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Analogausgang: Analogspannungsausgang•Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Externer Eingang (Eingang 1, Eingang 2, Eingang 3)Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx.
Maximale Anzahl anschließbarer ControllerUp to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Umweltbeständigkeit: Umgebungsfeuchtigkeit35 to 85 % RH, Storage: 35 to 85 % RH
Umweltbeständigkeit: Stoßfestigkeit98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each
Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3)NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Umweltbeständigkeit: Umgebungstemperatur-10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each
Umweltbeständigkeit: Isolationswiderstand20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Umweltbeständigkeit: Spannungsfestigkeit1,000 V AC for one minute between all supply terminals connected together and enclosure
Externer Eingang (Eingang 1, Eingang 2, Eingang 3): Eingangszeit• Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): AlarmausgangOpen when alarm occurs
Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): BeurteilungsausgangN.O. / N.C. switching type
Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): KurzschlussschutzIncorporated (automatic reset type)

Produktbeschreibung

HG-T Laser Displacement Sensor. High Functionality Master Controller, PNP Output
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung