| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Gewicht | 450 g approx. |
| Details | Controller |
| Produkt | Ultra High-speed High-precision Laser Displacement Sensor |
| Material | Case: Polycarbonate |
| Zubehör | USB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc. |
| Teilenummer | HL-C2C |
| Reset-Eingang | Reset is done when connected to Common (-).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less) |
| Alarmausgang | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between alarm output and Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current) |
| Produktname | Ultra High-speed・High-precision Laser Displacement Sensor HL-C2 |
| Zeiteingang | ON at/during connection to Common (-)(depending on analysis mode)Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less) |
| Abtastrate | 10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms |
| Stroboskop-Ausgang | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between strobe output to Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current) |
| Produktnummer | HL-C2C |
| Versorgungsspannung | 24 V DC plus or minus 10 % including ripple 0.5 V (P-P) |
| Null-Eingang | Zero set is ON when connected with Common (-).Zero set turns to OFF after continuously connected to Common (-) for one second.Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less) |
| Anzeige: Leistung | Green LED (lights up at power on) |
| Aktueller Verbrauch | 500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected) |
| Anzeige: Alarm 1 | Red LED (lights up when OUT1 can not be measured due to insufficient amount of light) |
| Anzeige: Alarm 2 | Red LED (lights up when OUT2 can not be measured due to insufficient amount of light) |
| Laser-Steuereingang | Laser emission is stopped when connected to Common (-).Laser is emitted immediately after opened.Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less) |
| Speicheränderungseingabe | Memory is specified when connected to Common (-).Applied voltage: 30 V DC or less(Leak current: 0.1 mA or less) |
| Connectale Sensorkopf | Number of connectable units: Max. 2 units. |
| Fernverriegelungseingang | Laser emission is delayed when connected to Common (-).Laser emission stop at openApplied voltage: 30 V DC or less(Leak current: 0.1 mA or less) |
| Analogausgang: Strom | Current output scale: 4 to 20 mA/F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max., Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value. |
| Analogausgang: Spannung | Voltage output scale: -5 to +5 V/F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mV, Linearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 Ohm , Response delay time: 1.5 micro s/V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value. |
| Beurteilungsergebnis (HI, GO, LO) | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less[between judgment output to Common(-)]- Residual voltage: 1 V or less(at 100 mA sink current) |
| Alarmausgang: Ausgangsfunktion | Opened when the amount of light is insufficient |
| Stroboskopausgang: Ausgangsbetrieb | Opened at data determination |
| Alarmausgang: Kurzschlussschutz | Incorporated |
| Blitzlichtausgang: Kurzschlussschutz | Incorporated |
| Indikator: Sensorkopf A Laserstrahlung | Green LED (lights up during or immediately before laser emission of sensor head A) |
| Indikator: Sensorkopf B Laserstrahlung | Green LED (lights up during or immediately before laser emission of sensor head B) |
| Umweltbeständigkeit: Umgebungsfeuchtigkeit | 35 to 85 %RH |
| Umweltbeständigkeit: Stoßfestigkeit | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each |
| Umweltbeständigkeit: Umgebungstemperatur | 0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit |
| Entscheidungsergebnis (HI, GO, LO): Ausgabeoperation | Opened at output operation |
| Umweltbeständigkeit: Vibrationsbeständigkeit | 10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each |
| Ausgang (HI, GO, LO): Kurzschlussschutz | Incorporated |