Wichtige Spezifikationen
Artikel:Specifications
Gewicht:450 g approx.
Details:Controllers(Ethernet communications port)
Produkt:Ultra High-speed- High-precision Laser Displacement Sensor
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Gewicht450 g approx.
DetailsControllers(Ethernet communications port)
ProduktUltra High-speed- High-precision Laser Displacement Sensor
MaterialCase: Polycarbonate
ZubehörUSB cable (2 m 6.562 ft long): 1 pc.Short bracket: 1 pc.Ferrite cores (E04SR200935A, by Seiwa Electric Mfg. Co., Ltd.): 3 pcs
TeilenummerHL-C21C-P
Reset-EingangPNP open-collector transistor- Reset is done when connected to external power (+).- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
AlarmausgangPNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between each output and +V)- Residual voltage: 1 V or less (at 100 mA source current)
ProduktnameUltra High-speed・High-precision Laser Displacement Sensor HL-C2
ZeiteingangPNP open-collector transistor- ON at / during connection to external power (+)(depending on analysis mode)- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Abtastrate10 micro s, 20 micro s, 40 micro s, 100 micro s, 200 micro s, 400 micro s, 1 ms, 2 ms
Stroboskop-AusgangPNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between each output and +V)- Residual voltage: 1 V or less (at 100 mA source current)
USB-SchnittstelleUSB 2.0 Full-speed (USB 1.1 compatible) compliant
ProduktnummerHL-C21C-P
Versorgungsspannung24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Null-EingangPNP open-collector transistor- Zero set is ON when connected with external power (+).- Zero set turns to OFF after continuously connected to external power (+) for one second.- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Anzeige: LeistungGreen LED (lights up at power on)
Aktueller Verbrauch500 mA approx. at 2 sensor heads connected350 mA approx. at 1 sensor head connected(100 mA approx. is additionally required when the mini console is connected)
Anzeige: Alarm 1Red LED (lights up when OUT1 can not be measured due to insufficient amount of light)
Anzeige: Alarm 2Red LED (lights up when OUT2 can not be measured due to insufficient amount of light)
Laser-SteuereingangPNP open-collector transistor- Laser emission is stopped when connected to external power (+).- Laser is emitted immediately after opened.- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
SpeicheränderungseingabePNP open-collector transistor- Memory is specified when connected to external power (+).- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Connectale SensorkopfNumber of connectable units: Max. 2 units.
FernverriegelungseingangPNP open-collector transistor- Laser emission is delayed when connected to IL (+).- Laser emission stops at open- Applied voltage: 30 V DC or less (Leak current: 0.1 mA or less)
Einstellungen / DatenanzeigeCompact console (optional)
Analogausgang: StromCurrent output scale: 4 to 20 mA / F.S (initial value)Output range during normal status: 2 to 24 mAOutput at abnormal status: 1 mA or 25 mAResolution: 3 micro A, Linearity plus or minus 0.05% F.S.Load impedance: 250 Ohm max.Response delay time: 10 micro s approx.(Note) The linearity is F.S.=16 mA to digital measurement value. Response delay time is the period after update of measurement value.
Analogausgang: SpannungVoltage output scale: -5 to +5 V / F.S (initial value)Output range during normal status: -10.0 to +10.0 VOutput at abnormal status: -10.8 V or +10.8 VResolution: 2 mVLinearity: plus or minus 0.05 % F.S.Max. 2 mA, output impedance 50 OhmResponse delay time: 1.5 micro s / V approx.(Note) The linearity is F.S.=20 V to digital measurement value. Response delay time is the period after update of measurement value.
Beurteilungsergebnis (HI, GO, LO)PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between each output and +V)- Residual voltage: 1 V or less (at 100 mA source current)
Alarmausgang: AusgangsfunktionOpened when the amount of light is insufficient
Stroboskopausgang: AusgangsbetriebOpened at data determination
Alarmausgang: KurzschlussschutzIncorporated
Blitzlichtausgang: KurzschlussschutzIncorporated
Indikator: Sensorkopf A LaserstrahlungGreen LED (lights up during or immediately before laser emission of sensor head A)
Indikator: Sensorkopf B LaserstrahlungGreen LED (lights up during or immediately before laser emission of sensor head B)
Umweltbeständigkeit: Umgebungsfeuchtigkeit35 to 85 %RH
Umweltbeständigkeit: Stoßfestigkeit196 m / s2 acceleration (20G approx.) in X, Y, and Z directions for three times each
Umweltbeständigkeit: Umgebungstemperatur0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Entscheidungsergebnis (HI, GO, LO): AusgabeoperationOpened at output operation
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55 Hz frequency (period: 1 min.), 0.75 mm 0.030 in amplitude in X, Y and Z directions for 30 min. each
Ausgang (HI, GO, LO): KurzschlussschutzIncorporated

Produktbeschreibung

High performance analog laser high resolution controller, HL-C2 series, Ethernet port, analog output ±5V/ 4 - 20mA, PNP digital output
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top