| Parameter | Wert |
|---|---|
| When communication unitis connected | |
| Artikel | Specifications |
| Kabel | 0.2 mm22-core (brown and blue lead wires) / 0.15 mm27-core composite cable, 2 m6.562 ftlong |
| Details | Master unit / High performance type |
| Produkt | Controller |
| Material | Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Nettogewicht | 140 g approx. |
| Teilenummer | HG-TC101 |
| 1 bis 7 Einheiten | 1 to 6 units |
| Produktname | Thru-beam Type Digital Displacement Sensor HG-T |
| 8 bis 15 Einheiten | 7 to 14 units |
| Anzeigebereich | -199.999 to 199.999 mm-7.874 to 7.874 in |
| Abtastrate | 1 ms (standard sampling) / 0.5 ms (high-speed sampling) |
| Produktnummer | HG-TC101 |
| Versorgungsspannung | 24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Verschmutzungsgrad | 2 |
| Bildschirmauflösung | 1 μm0.039 mil |
| Betriebshöhe | 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Aktueller Verbrauch | 100 mA or less (when sensor head is connected)(Note) : Current consumption does not include analog current output. |
| Einhaltung gesetzlicher Bestimmungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Geeigneter Sensorkopf | HG-T1010、HG-T1110 |
| Externe Eingangsumschaltung | Input 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop". |
| Externe Ausgangsumschaltung | Output 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2. |
| Durchschnittliche Anzahl (Reaktionszeit) | 1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Anzahl der verbundenen Slave-Einheiten | Maximum sink current and sourcecurrent of control output |
| Störungsverhinderungsfunktion | Incorporated(Note) : This function operates for each set of 4 connected controllers. |
| Umweltbeständigkeit: Schutz | IP40(IEC) |
| Analogausgang: Analoger Stromausgang | •Current output range: 4 to 20 mA/F.S. (default value)•Linearity: ±0.25 % F.S.•Output when alarm occurs: 0 mA•Load impedance: 250 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Analogausgang: Analogspannungsausgang | •Voltage output range: 1 to 5 V/F.S. (default value)•Linearity: ±0.05 % F.S.•Output when alarm occurs: 5.2 V•Output impedance: 100 Ω max.(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output. |
| Externer Eingang (Eingang 1, Eingang 2, Eingang 3) | Non-contact input or NPN open-collector transistor•Input conditionsInvalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC•Input impedance: 10 kΩ approx.Non-contact input or PNP open-collector transistor•Input conditionsInvalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC•Input impedance: 10 kΩ approx. |
| Maximale Anzahl anschließbarer Controller | Up to 15 slave units can be connected to a master unit.(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
| Umweltbeständigkeit: Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Umweltbeständigkeit: Stoßfestigkeit | 98m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3) | NPN open-collector transistor•Maximum sink current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and 0 V)•Residual voltage: 1.5 V or less (at 50 mA sink current)•Leakage current: 0.1 mA or lessPNP open-collector transistor•Maximum source current: 50 mA (Note)•Applied voltage: 30 V DC or less (between output and +V)•Residual voltage: 1.5 V or less (at 50 mA source current)•Leakage current: 0.1 mA or less(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Umweltbeständigkeit: Umgebungstemperatur | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃-4 to +140 ℉(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.Number of connected slave unitsMaximum sink current and sourcecurrent of control outputAmbient temperatureWhen communication unitis connected1 to 7 units1 to 6 units20 mA-10~+45℃+14 to +113 ℉8 to 15 units7 to 14 units10 mA |
| Umweltbeständigkeit: Vibrationsbeständigkeit | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2(58 to 150 Hz) in X, Y and Z directions for two hours each |
| Umweltbeständigkeit: Isolationswiderstand | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Umweltbeständigkeit: Spannungsfestigkeit | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
| Externer Eingang (Eingang 1, Eingang 2, Eingang 3): Eingangszeit | • Trigger input: 2 ms or more (ON)• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling). |
| Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): Alarmausgang | Open when alarm occurs |
| Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): Beurteilungsausgang | N.O. / N.C. switching type |
| Steuerausgang (Ausgang 1, Ausgang 2, Ausgang 3): Kurzschlussschutz | Incorporated (automatic reset type) |