Servicezeiten: Montag bis Freitag 9:00-18:00
UHGS1010AC - UHGS1010AC HG-S1010-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..
Vorrätig Top‑Produkt

UHGS1010AC

UHGS1010AC HG-S1010-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..

$0.00USD
4292 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Bemerkung:Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Schlaganfall:10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Gewicht:Net weight: 80 g approx.
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
BemerkungWhere measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Schlaganfall10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
GewichtNet weight: 80 g approx.
DetailsAir-driven type10 mm0.394 intype General purpose
ProduktContact-Type Digital Displacement Sensor
MaterialBody: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM(Note) : The probe is also available as an option.
ZubehörSensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Auflösung0.5 μm0.02 mil
TeilenummerHG-S1010-AC
ProduktnameContact-Type Digital Displacement Sensor HG-S
Verwendbare FlüssigkeitClean air (Dew point temperature: -10 ℃+14 ℉or less)
Abtastrate1 ms
ProduktnummerHG-S1010-AC
Anwendbares RohrOutside diameter: ø4 mmø0.157 in/ Inside diameter: ø2.5 mmø0.098 in
Messkraft・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
Messbereich10 mm0.394 in(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
ErdungsmethodeCapacitor grounding
Verschmutzungsgrad2
Hot-Swap-FunktionIncorporated
Betriebshöhe2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
BetriebsanzeigeEquipped (2-color LED: Orange / Green)
Abweichung der Spitze35 μm1.378 mil(typical value)
Anwendbarer ControllerHG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Isolationswiderstand100 MΩ or more at 250 V DC
Einhaltung gesetzlicher BestimmungenCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Arbeitsdruckbereich0.14 to 0.16 MPaWith no seal cap mounted : 0.035 to 0.045 MPa
Anzeigegenauigkeit (PP)Full range: 2.0 μm0.079 milor lessLimited range: 1.0 μm0.039 milor less(any 60 μm2.362 mil)
PositionserkennungsmethodeOptical absolute linear encoder method
Fähigkeit, Druck zu widerstehen0.2 MPa
Umweltbeständigkeit: SchutzIP67 (IEC)With no seal cap mounted : -(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Umweltbeständigkeit: Umgebungsfeuchtigkeit35 to 85 % RH, Storage: 35 to 85 % RH
Umweltbeständigkeit: Stoßfestigkeit1,960 m/s2acceleration in X, Y, and Z directions three times each
Umweltbeständigkeit: Umgebungstemperatur-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage: -20 to +60 ℃-4 to +140 ℉
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each

Produktbeschreibung

HG-S - Contact measurement sensor. Sensor head with pneumatic actuator. Resolution 0.5μm. Precision 2μm. Range 10mm