| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 5-core composite cable, 2 m6.5617 ftlong |
| Gewicht | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) |
| Details | Measurement center 400mm 15.748 in type |
| Produkt | CMOS type Micro Laser Distance Sensor |
| Material | Enclosure: Aluminum die-castFront cover: Acrylic |
| Linearität | ±0.2 % F.S. (Measuring distance 200 to 400 mm7.874 to 15.748 in)±0.3 % F.S. (Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Schutz | IP67 (IEC) |
| Teilenummer | HG-C1400-P |
| Lichtquelle | Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note) ]Max. output: 1 mWemission peak wavelength: 655 nm0.026 mil(Note) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Produktname | CMOS type Micro Laser Distance Sensor HG-C |
| Strahldurchmesser | ø500 μm19.6851 milapprox.(Note) This is the size in the measurement center distance. These values were defined by using 1/e2(13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. |
| Wiederholbarkeit | 300 μm11.811 mil(Measuring distance 200 to 400 mm7.874 to 15.748 in)800 μm31.496 mil(Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Ansprechzeit | Switchable between 1.5 ms / 5 ms / 10 ms |
| Steuerausgang | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 30 V DC or less (Between control output to +V)- Residual voltage: 1.5 V or less (At 50 mA source current)- Leakage current: 0.1 mA or less |
| Externer Eingang | PNP non-contact input- Input conditionsInvalid: 0 to +0.6 V DC or OpenValid: +4 to +V DC- Input impedance: 10 kΩ approx. |
| Produktnummer | HG-C1400-P |
| Versorgungsspannung | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less |
| Kabelverlängerung | Extension up to total 10 m393.701 ftis possible with 0.3 mm2, or more, cable. |
| Messbereich | ±200 mm7.874 in |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Verschmutzungsgrad | 2 |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Betriebshöhe | 2,000 m6561.680 ftor less |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +45 ℃-14 to 113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to 140 ℉ |
| Aktueller Verbrauch | 40 mA or less (at 24V DC supply voltage)65 mA or less (at 12V DC supply voltage)Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) |
| Vibrationsfestigkeit | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Abstand zwischen Messmittelpunkt | 400 mm15.748 in |
| Temperatureigenschaften | 0.03% F.S./℃ |
| Steuerausgang: Ausgangsfunktion | Either Light-ON or Dark-ON |
| Analogausgang: Analoger Stromausgang | • Output range: 4 to 20mA (at alarm: 0mA)• Output impedance: 300Ω or lessNote : Analog current output has been added from shipment in August 2016. |
| Analogausgang: Analogspannungsausgang | • Output range: 0 to 5 V (at alarm: +5.2 V)• Output impedance: 100Ω |
| Steuerausgang: Kurzschlussschutz | Incorporated (Auto reset type) |
| Anwendbare Vorschriften und Zertifizierungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification(Note) : The UL/c-UL certified products have been shipped since April, 2017. |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung