| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | Discrete wire type: 0.2 mm24-core PVC cable, 2 m6.562 ftlongM12 connector type: 0.2 mm24-core PVC cable with connector, 0.3 m0.984 ftlong |
| Bemerkung | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃+68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
| Gewicht | 30 g approx. (without cable), 80 g approx. (including cable) |
| Details | Discrete wire type |
| Produkt | CMOS Type Micro Laser Distance Sensor |
| Material | Enclosure: Aluminum die-cast, Front cover: Acrylic |
| Linearität | ±0.2 % F.S.(Measuring distance 200 to 400 mm7.874 to 15.748 in)±0.3 % F.S.(Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Schutz | IP67(IEC) |
| Teilenummer | HG-C1400L3-P |
| Lichtquelle | Red semiconductor laser Class 2 [IEC / EN/ JIS / GB / KS / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm0.026 mil(Note:)This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3. |
| Produktname | CMOS type Micro Laser Distance Sensor HG-C1000L |
| Strahldurchmesser | ø500 μm19.685 milapprox. |
| Wiederholbarkeit | 300 μm11.811 mil(Measuring distance 200 to 400 mm7.874 to 15.748 in)800 μm31.496 mil(Measuring distance 400 to 600 mm15.748 to 23.622 in) |
| Ansprechzeit | Switchable between 1.5 ms / 5 ms / 10 ms |
| Steuerausgang | PNP open-collector transistor• Maximum source current: 50 mA• Applied voltage: 30 V DC or less (Between control output to +V)• Residual voltage: 1.5 V or less (at 50 mA source current)• Leakage current: 0.1 mA or less |
| Produktnummer | HG-C1400L3-P |
| Versorgungsspannung | 24 V DC ±10 % Ripple P-P 10 % |
| Kabelverlängerung | Extension up to total 20 m65.617 ftis possible with 0.3 mm2, or more, cable. |
| Messbereich | ±200 mm7.874 in |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Verschmutzungsgrad | 2 |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Betriebshöhe | 2,000 m6561.680 ftor less |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +45℃-14 to 113℉(No dew condensation or icing allowed), Storage: -20 to +60℃-4 to 140℉ |
| Aktueller Verbrauch | 40 mA or less (at 24 V DC supply voltage) |
| Vibrationsfestigkeit | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Abstand zwischen Messmittelpunkt | 400 mm15.748 in |
| Temperatureigenschaften | 0.03%F.S./℃ |
| Steuerausgang: Ausgangsfunktion | Switchable between either Light-ON or Dark-ON |
| Kommunikationsausgang (C/Q): Baudrate | COM3 (230.4 kbps) |
| Steuerausgang: Kurzschlussschutz | Incorporated (auto reset type) |
| Anwendbare Vorschriften und Zertifizierungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification |
| Kommunikationsausgabe (C/Q): Prozessdaten | 4 byte |
| Kommunikationsausgang (C/Q): Minimale Zykluszeit | 1.0 ms |
| Kommunikationsausgang (C/Q): IO-Link-Kommunikation | IO-Link Specification V1.1 |