Servicezeiten: Montag bis Freitag 9:00-18:00
UHGC1100 - UHGC1100 HG-C1100 PANASONIC Compact Laser Displacement Sensor, 100mm+-35mm, NPN, 0-5V/4-20mA, cable 2m
Vorrätig Top‑Produkt

UHGC1100

UHGC1100 HG-C1100 PANASONIC Compact Laser Displacement Sensor, 100mm+-35mm, NPN, 0-5V/4-20mA, cable 2m

$0.00USD
4278 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Kabel:5-core composite cable, 2 m6.5617 ftlong
Gewicht:Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
Details:Measurement center 100mm 3.937 in type
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Kabel5-core composite cable, 2 m6.5617 ftlong
GewichtNet weight: 35 g approx. (without cable), 85 g approx. (including cable)
DetailsMeasurement center 100mm 3.937 in type
ProduktCMOS type Micro Laser Distance Sensor
MaterialEnclosure: Aluminum die-castFront cover: Acrylic
Linearität±0.1%F.S.
SchutzIP67 (IEC)
TeilenummerHG-C1100
LichtquelleRed semiconductor laser Class 2 (IEC / EN/ JIS / GB / KS / FDA) / Class II (FDA)(Note)Max. output: 1mWemission peak wavelength: 655nm 0.026 mil(Note) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
ProduktnameCMOS type Micro Laser Distance Sensor HG-C
Strahldurchmesserø120 μm4.7241 milapprox.(Note) This is the size in the measurement center distance. These values were defined by using 1 / e2(13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
Wiederholbarkeit70 μm2.756 mil
AnsprechzeitSwitchable between 1.5 ms / 5 ms / 10 ms
SteuerausgangNPN open-collector transistor- Maximum sink current: 50mA- Applied voltage: 30V DC or less (Between control output to 0V)- Residual voltage: 1.5V or less (At 50mA sink current)- Leakage current: 0.1 mA or less
Externer EingangNPN non-contact input- Input conditionsInvalid: +8 to +V DC or OpenValid: 0 to +1.2V DC- Input impedance: 10kΩ approx.
ProduktnummerHG-C1100
Versorgungsspannung12 to 24V DCplus or minus 10% Ripple P-P 10%
KabelverlängerungExtension up to total 10 m393.701 ftis possible with 0.3 mm2, or more, cable.
Messbereich±35mm1.328 in
Umgebungsfeuchtigkeit35 to 85% RH, Storage: 35 to 85% RH
Verschmutzungsgrad2
Stoßfestigkeit500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each
Betriebshöhe2,000 m6561.680 ftor less
UmgebungsbeleuchtungsstärkeIncandescent light: 3,000 ℓx or less at the light-receiving face
Umgebungstemperatur-10 to +45 ℃-14 to 113 ℉(No dew condensation or icing allowed), Storage: -20 to +60 ℃-4 to 140 ℉
Aktueller Verbrauch40 mA or less (at 24V DC supply voltage)65 mA or less (at 12V DC supply voltage)Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
Vibrationsfestigkeit10 to 55 Hz (period: 1 min.) frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each
Abstand zwischen Messmittelpunkt100mm3.937 in
Temperatureigenschaften0.03% F.S. /℃
Steuerausgang: AusgangsfunktionEither Light-ON or Dark-ON
Analogausgang: Analoger Stromausgang• Output range: 4 to 20mA (at alarm: 0mA)• Output impedance: 300Ω or lessNote : Analog current output has been added from shipment in August 2016.
Analogausgang: Analogspannungsausgang• Output range: 0 to 5 V (at alarm: +5.2 V)• Output impedance: 100Ω
Steuerausgang: KurzschlussschutzIncorporated (Auto reset type)
Anwendbare Vorschriften und ZertifizierungenCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification(Note) : The UL/c-UL certified products have been shipped since April, 2017.

Produktbeschreibung

Micro Displacement Laser Sensor, measurement range 100mm. ± 35mm., repeatability 70μm., beam diameter approx. 120μm., digital NPN output, analog output 0-5V / 4-20mA, cable 2m
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top