| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Bemerkung | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.The values specified above are applied only to the controller. |
| Gewicht | Net weight : 25 g approx. (excluding connector attached cable),Gross weight : 140 g approx. |
| Details | Controller |
| Anzeige | 4 digits +4 digits 3-color LCD display(Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Produkt | Head-separated Dual display Digital Pressure Sensor [For gas & liquid] |
| Material | Enclosure : PBT (glass fiber reinforced),LCD display : Acrylic,Mounting threaded part : Brass (nickel plated),Switch part : Silicone rubber |
| Schutz | IP40 (IEC) |
| Zubehör | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set |
| Teilenummer | DPC-L101 |
| Kabellänge | Total length up to 100 m328.084 ft(less than 30 m98.425 ftwhen conforming to CE marking) is possible with 0.3 mm2, or more, cable. |
| Produktname | Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100 |
| Analogausgang | ・ Output current : 1 to 5 V DC・ Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V)・ Span : within 4 V ±0.5 % F.S.・ Linearity : within ±0.1 % F.S.・ Output impedance : 1 kΩ approx.・ Output current : 4 to 20 mA・ Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V)・ Span : within 16 mA ±1.5 % F.S.・ Linearity : within ±0.1 % F.S.・ Load resistance : 250 Ω (max.) |
| Produktnummer | DPC-L101 |
| Versorgungsspannung | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage : 35 to 85 % RH |
| Stoßfestigkeit | 100 m/s2acceleration in X, Y and Z directions three times each |
| Verbindungsmethode | Connector |
| Stromverbrauch | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)Excluding the current consumption of sensor head and analog output current |
| Vergleichsausgabe | NPN open-collector transistor (2 outputs)・ Maximum sink current : 50 mA・ Applied voltage : 30 V DC or less(between comparative output and 0 V)・ Residual voltage : 1 V or less (at 50 mA sink current) |
| Einstelldruckbereich | [DPH-L113V]-1.177 to +1.177 MPa-12.00 to +12.00 kgf/cm2-11.77 to +11.77 bar-170.6 to +170.6 psi[DPH-L113]-1.070 to +1.070 MPa-10.91 to +10.91 kgf/cm2-10.70 to +10.70 bar-155.2 to +155.2 psi[DPH-L133]-3.74 to +3.74 MPa-38.1 to +38.1 kgf/cm2-37.4 to +37.4 bar-542 to +542 psi[DPH-L114]-10.70 to +10.70 MPa-109.1 to +109.1 kgf/cm2-107.0 to +107.0 bar-1552 to +1552 psi[DPH-L154]-53.5 to +53.5 MPa-545 to +545 kgf/cm2-535 to +535 bar-1980 to +7760 psi(Note) : Values differ depending on a connected sensor head. |
| Umgebungstemperatur | -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed), Storage : -10 to +60 ℃+14 to +140 ℉ |
| Betriebsanzeige | Orange LED(Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON ) |
| Nenndruckbereich | DPH-L113V : -0.1 to +1 MPaDPH-L113 : 0 to +1 MPaDPH-L133 : 0 to +3.5 MPaDPH-L114 : 0 to +10 MPaDPH-L154 : 0 to +50 MPa(Note) : Values differ depending on a connected sensor head. |
| Vibrationsfestigkeit | 10 to 500 Hz frequency, double amplitude 3 mm0.118 inor maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm0.030 inor maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Isolationswiderstand | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Anwendbare Vorschriften | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Eingänge: Externer Eingang | ON voltage : 0.4 V DC or lessOFF voltage : 5 to 30 V DC, or openInput impedance : 10 kΩ approx.Input time : 1 ms or more |
| Druckauflösung einstellen | DPH-L113V : 0.001 MPaDPH-L113 : 0.001 MPaDPH-L133 : 0.01 MPaDPH-L114 : 0.01 MPaDPH-L154 : 0.1 MPa(Note): Values differ depending on a connected sensor head. |
| Spannungsfestigkeit | 500 V AC for one min. between all supply terminals connected together and enclosure |
| Eingänge: Sensorkopf-Eingang | Input voltage range : 1 to 5 V DC (over rated pressure range) |
| Temperaturcharakteristik | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃+68 ℉) |
| Vergleichsausgabe: Hysterese | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
| Vergleich der Ausgänge: Ausgabemodi | EASY mode / Hysteresis mode / Window comparator mode |
| Vergleichsergebnis: Wiederholbarkeit | Within ±0.2 % F.S. |
| Vergleichsausgabe: Reaktionszeit | 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Anzeige: Anzeigbarer Druckbereich | [DPH-L113V]-0.155 to +1.022 MPa-1.58 to +10.42 kgf/cm2-1.55 to +10.22 bar-22.4 to +148.2 psi[DPH-L113]-0.050 to +1.020 MPa-0.51 to +10.40 kgf/cm2-0.50 to +10.20 bar-7.2 to +148.0 psi[DPH-L133]-0.17 to +3.57 MPa-1.7 to +36.4 kgf/cm2-1.7 to +35.7 bar-24 to +518 psi[DPH-L114]-0.50 to +10.20 MPa-5.1 to +104.0 kgf/cm2-5.0 to +102.0 bar-72 to +1480 psi[DPH-L154]-2.5 to +51.0 MPa-25 to +520 kgf/cm2-25 to +510 bar-360 to +7400 psi(Note): Values differ depending on a connected sensor head. |
| Vergleichsausgabe: Ausgabeoperation | NO / NC, selectable by key operation |
| Vergleichsausgang: Kurzschlussschutz | Incorporated |
Technische Spezifikationen und Leistungsdaten