Wichtige Spezifikationen
Artikel:Specifications
Gewicht:Net weight: 300 g approx.
Details:Controller
Produkt:Ultra High-speed Laser Displacement Sensor [CCD Style]
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
GewichtNet weight: 300 g approx.
DetailsController
ProduktUltra High-speed Laser Displacement Sensor [CCD Style]
Zubehör-
TeilenummerHL-C1C-M
AlarmausgangPhoto-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between alarm output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
KabellängePower line: Less than 10 m 32.808 ftSignal line: Less than 30 m 98.425 ft
ProduktnameUltra High-speed Laser Displacement Sensor HL-C1(Discontinued)
AbtastrateSelectable from 100 micro s / 144 micro s / 200 micro s / 255 micro s / 332 micro s / 498 micro s / 1,000 micro s
HaltefunktionenSelectable from NORMAL / P-P / PEAK / VALLEY(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
ProduktnummerHL-C1C-M
Versorgungsspannung24 V DC plus or minus 10 % including ripple 0.5 V (P-P)
Digitale FilterHigh pass: OFF, 10 to 2,000 Hz (9 steps)Low pass: OFF, 10 to 2,000 Hz (9 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Indikatoren: DUNKELRed LED (lights up upon disabled measurement due to insufficient light at sensor head 1 or 2)
Nullpunkt gesetzt EIN EingangZero set: ON when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Kalibrierung: Spanne0.9000 to 1.1000(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Nullpunkt-OFF-EingangZero set: OFF when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input
Kalibrierung: Verschiebungplus or minus 20.0000 mm plus or minus 0.787 in(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Aktueller VerbrauchWhen 1 sensor is connected: 430 mA approx.When 2 sensors are connected: 550 mA approx.
Indikatoren: HELLRed LED (lights up upon disabled measurement due to excessive light at sensor head 1 or 2)
BerechnungsfunktionenL plus or minus KA, L plus or minus KB, L plus or minus K (A plus or minus B)A, B: Sensor head 1, Sensor head 2 measurement values, L = plus or minus 999.9999, K = 0.0001 to 99.9999(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Serielle Ein-/AusgabeRS-232C
Connectale SensorkopfMaximum 2 sensor heads
Analogausgang: StromOutput current: 4 to 20 mA/F.S. [default setting when diffuse reflective mode is selected (Note 2)]Output range: 0 to 29.5 mA (maximum of 25 mA at max. load impedance)Load impedance: 250 Ohm or less(Note 1) The maximum analog output current will vary with load impedance.(Note 2) If specular reflective mode is selected, then the default setting is 5.6 to 18.4 mA/F.S.
Analogausgang: SpannungOutput voltage: plus or minus 5 V/F.S. [default setting when diffuse reflective mode is selected (Note) ]Output range: -10.9 to +10.9 VOutput current: Max. 2 mA, Output impedance: 50 Ohm(Note) If specular reflective mode is selected, then the default setting is plus or minus 4 V/F.S.
Durchschnittliche Anzahl der ProbenOFF, 2 to 32,768 times (16 steps)(Note) These values can be set using the command input from external equipment via the compact console and RS-232C interface.
Beurteilungsergebnisse (O1, O2)Photo-MOS relay- Maximum load current: 50 mA- Applied voltage: 30 V DC or less (between judgment output and COM)- ON impedance: 35 Ohm or less- Operation time: Max. 2 ms
Indikatoren: LaseremissionGreen LED (lights up during laser emission from sensor head 1 or sensor head 2, or immediately before laser emission)
Temperatureigenschaftenplus or minus 0.01 % F.S./degrees
Zeiteingang (Laseremission)Laser emission stops or continues when voltage (using input voltage: 12 to 24 V DC, maximum input voltage: 30 V DC) is input or there is an open circuit: determined based on input mode selection.
Alarmausgang: AusgangsfunktionOpened when the amount of light is excessive or insufficient.
Alarmausgang: KurzschlussschutzIncorporated
Umweltbeständigkeit: Umgebungsfeuchtigkeit35 to 85 % RH, Storage: 35 to 85 % RH
Umweltbeständigkeit: Stoßfestigkeit196 m/s2 (20 G approx.) in X, Y and Z directions for 3 times each
Beurteilungsergebnisse (O1, O2): AusgabeoperationOpened or closed when the threshold value is reached. Determined based on judgment output mode selection. (The threshold value varies with the hysteresis setting.)
Umweltbeständigkeit: Umgebungstemperatur0 to +50 degrees +32 to +122 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55 Hz frequency (period: 1 min.) 0.75 mm 0.030 in amplitude in X,Y and Z directions for 30 min. each
Beurteilungsergebnisse (O1, O2): NutzungskategorieDC-12 or DC-13
Ausgänge für die Beurteilung (O1, O2): KurzschlussschutzIncorporated

Produktbeschreibung

More details
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie