Servicezeiten: Montag bis Freitag 9:00-18:00
WM1496AV63BPG - WM1496AV63BPG CARLO GAVAZZI MOUNTING Panel POWER SUPPLY 48VAC OUTPUT DIGITAL INPUT DC output (Open Collector..
Vorrätig Top‑Produkt

WM1496AV63BPG

WM1496AV63BPG CARLO GAVAZZI MOUNTING Panel POWER SUPPLY 48VAC OUTPUT DIGITAL INPUT DC output (Open Collector..

$0.00USD
4015 auf Lager
Lieferanteninformation
CARLO GAVAZZI
CARLO GAVAZZI
Produkte: 10094
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Produktbeschreibung

Three-Phase Power Analyzer, Built-in Programming Keyboard, Basic Version, 96x96 Panel
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Technische Details

Energy ManagementPower AnalyzerType WM14-96 “Basic Version”• Class 1 (active energy)• Class 2 (reactive energy)• Accuracy ±0.5 F.S. (current/voltage)• Power analyzer• Display of instantaneous variables: 3x3 digit• Display of energies: 8+1 digit• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz• Amax, Admd max, Wdmdmaxindication• Energy measurements: kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Power supply: 24V, 48V, 115V, 230V, 50-60Hz 18 to 60VDC• Optional dual pulse output• Alarms (visual only) VLN, An• Optional galvanically insulated measuring inputsProduct Description• Protection degree (front): IP65• Front dimensions: 96x96mm• Optional RS422/485 serial portHow to order WM14-96 AV5 3 D PGX3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables. Housing for panel mounting,(front) protection degree IP65, and optional RS485 serial port or dual pulse out- put. Parameters pro- grammable by means of CptBSoft.Model Range code SystemPower supplyOptionHow to orderCptBSoftType SelectionCptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables.Range codesAV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 VAV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6AInputspecificationsRated inputsSystem3 :1-2-3-phase, balanced/unbalanced load,with or without neutralPower supplyA: 24VAC-15+10%, 50-60HzB: 48VAC-15+10%, 50-60HzC: 115VAC-15+10%, 50-60HzD: 230VAC-15+10%, 50-60Hz3:18 to 60VDC (not available in case of SG or PG options)OptionsX: NoneS: RS485 portSG:RS485+galvanic insu- lated measurig inputsPG:Dual pulse output+ galvanically insulated measuring inputs.0.03Ato0.25A:±(2%FS +5DGT)Current “X-S options” 3 (non insulated each other)Current “SG-PG options”3 (insulated each other) Voltage4Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS:57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(0.5%FS+7DGT) Phase-phase voltage ±(1.5% FS +1 DGT)Phase-neutral voltage ±(0.5% FS + 1 DGT)Active and Apparent power,0.25 to 6A: ±(1% FS +1DGT)0.03A to 0.25A: ±(1% FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)Active energy “X-S option” Class 2 (start up “I”: 30mA) Reactive energy “X-S option”Class 3 (start up “I”: 30mA) Active energy “SG-PG opt.” Class 1 (start up “I”: 30mA) Reactive energy “SG-PG opt.” Class 2 (start up “I”: 30mA) Frequency±0.1Hz (48 to 62Hz)Additional errorsHumidity≤0.3% FS, 60% to 90% RHTemperature drift≤ 200ppm/°CSampling rate1400 samples/s @ 50Hz1700 samples/s @ 60HzDisplay refresh time700msDisplayTypeLED, 14mmRead-out for instant. var.3x3 DGTRead-out for energies 3+3+3 DGT (Max indication:999 999 99.9)Specifications are subject to change without noticeWM14 96 DS ENG2005081

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top