Servicezeiten: Montag bis Freitag 9:00-18:00
UTZERVWANS01 - UTZERVWANS01 ER-VWANS PANASONIC Replacement silicone nozzles ERVW series
Vorrätig Top‑Produkt

UTZERVWANS01

UTZERVWANS01 ER-VWANS PANASONIC Replacement silicone nozzles ERVW series

$0.00USD
4218 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Gewicht:Net weight: 110 g approx., Gross weight: 180 g approx.
Details:Spot type
Produkt:Thin-type Ionizer
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
GewichtNet weight: 110 g approx., Gross weight: 180 g approx.
DetailsSpot type
ProduktThin-type Ionizer
MaterialEnclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten
ZubehörConnector attached cable: 1 pc. (length 0.5 m1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc.
Ionengleichgewichtplus or minus10 V or less(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
TeilenummerER-VW
ProduktnameThin-type Ionizer ER-VW
E/A-AnschlussFor power & input / output: 8-pin connector, For connection: 9-pin connector
ProduktnummerER-VW
Versorgungsspannung24 V DC plus or minus 10 %
Umgebungsfeuchtigkeit35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH
Geeignete FlüssigkeitAir (dried clean air)(Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ℉) and an air filter (mesh size around 0.01 microm0.0004 mil).
EntladungsmethodeHigh frequency AC method
Ozonbildung0.05 ppm or less(Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm11.811 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa.
Verbindbare EinheitenMaximum number of connectable units: 5 (Including this unit)
Zugeführter Luftstrom60 liter/min. (ANR) or less
Luftdruckbereich0.05 to 0.5 MPa
GehäuseerdungCapacitor earth
Umgebungstemperatur0 to +55 ℃+32 to +131 ℉(No dew condensation allowed), Storage: –10 to +65 ℃+14 to +149 ℉
Zeit für die Ladungsentnahme1 sec. or less (plus or minus1,000 V to plus or minus100 V)(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm3.937 infrom the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Aktueller Verbrauch120 mA or less
Reset-Eingang (RESET)In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR
Ausgabe: AusgabeoperationCheck output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normalError output (ERROR): OFF when abnormal discharge is detected, ON when operation is normalDischarge output (DSC) (Note): ON when discharging, OFF when discharge halts(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Entladeausgangsspannung2,000 V approx.
Indikatoren:Prüfen (CHECK)Orange LED (lights up when the discharge needle is dirty or worn, etc.)
Indikatoren: Fehler (FEHLER)Red LED (lights up when abnormal discharge is detected)
Indikatoren: Leistung (LEISTUNG)Green LED (lights up when the power is ON)
Indikatoren: Entladung (DSC)Green LED (lights up when discharging)(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Entladestopp-Eingang (DSC AUS)Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)(Note:"DSC" is an abbreviated name of "DISCHARGE".)
Indikatoren: Luftüberwachung (AIR)Orange LED (lights up when no air is being supplied)(Note) Discharge halts when lights up.
Ausgang: KurzschlussschutzIncorporated
Ausgabe [Prüfen (CHECK) Fehler (ERROR) Entladen (DSC)]NPN open-collector transistor• Maximum sink current: 50 mA• Applied voltage: 30 V DC or less (between output and 0 V)• Residual voltage: 1 V or less (at 50 mA sink current)(Note:"DSC" is an abbreviated name of "DISCHARGE".)

Produktbeschreibung

ERVW Series Replacement Silicone Nozzles
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top