Wichtige Spezifikationen
Artikel:Specifications
PFHD:Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD:More than 100 years (Note:Mean time to dangerous failure (in years))
Gewicht:Net weight: 240 g approxGross weight: 450 g approx
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
PFHDRefer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFDMore than 100 years (Note:Mean time to dangerous failure (in years))
GewichtNet weight: 240 g approxGross weight: 450 g approx
DetailsController [High-functional]
ProduktCompact Type 4 Safety Beam Sensor
MaterialEnclosure: ABS
TeilenummerST4-C12EX
ProduktnameCompact Type 4 Safety Beam Sensor ST4
VerdrahtungskabelTerminal block connector: 0.2 to 1.5 mm2Power supply connector (A1, A2): 0.2 to 2.5 mm2
Netzspannung24 V DC +10-15 % Ripple P-P 10 % or less
AnsprechzeitOFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
ProduktnummerST4-C12EX
HilfsausgängePNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Lampenausgang stummschaltenAvailable muting lamp: 24 V DC, 1 to 10 W(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
AnschlussklemmeDetachable spring-cage terminal
Aktueller Verbrauch120 mA or less (excluding sensor head ST4-Ax)
Anwendbare StandardsIEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Geeigneter SensorkopfST4-Ax
Einhaltung der CE-KennzeichnungsrichtlinieMachinery Directive, EMC Directive, RoHS Directive
Hilfsausgänge: BetriebsmodusON when muting function is invalidOFF when muting function is validON when override function is invalidOFF when override function is validON when muting lamp is in normal conditionOFF when muting lamp is in abnormal conditionNegative logic of the control outputs (OSSD1, OSSD2)
Steuerausgänge (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Hilfsausgänge: SchutzschaltungIncorporated
Lampenausgang stummschalten: SchutzschaltungIncorporated
Umweltbeständigkeit: Umgebungsfeuchtigkeit30 to 85 % RH, Storage: 30 to 95 % RH
Umweltbeständigkeit: Stoßfestigkeit300 m/s2acceleration in X, Y and Z directions three times each
Umweltbeständigkeit: Umgebungstemperatur-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Umweltbeständigkeit: SchutzgradEnclosure: IP40 (IEC)Terminal: IP20 (IEC)
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Umweltbeständigkeit: Isolationswiderstand20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Steuerausgänge (OSSD 1, OSSD 2): BetriebsmodusON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interrupted(except during muting / override)OFF during lockout
Geeigneter Sensorkopf: Anzahl der ReihenschaltungenInterference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Steuerausgänge (OSSD1, OSSD2): SchutzschaltungIncorporated
Umweltbeständigkeit: Spannungsfestigkeit1,000 V AC for one min. between all supply terminals connected together and enclosure

Produktbeschreibung

ST4 Series High Functionality Control Unit
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung