| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.1 mm24-core PFA cabtyre cable, 2 m6.562 ftlong |
| Gewicht | Net weight: 45 g approxGross weight: 110 g approx |
| Details | Sensor [For chemical liquid] |
| Produkt | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] |
| Material | Enclosure: PFA |
| Schutz | IP65 / IP67 (IEC) |
| Teilenummer | SQ4-A22-P |
| Produktname | Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4 |
| Netzspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Produktnummer | SQ4-A22-P |
| Erfassungsobjekt | Sulfuric acid, Hydrochloric acid,Phosphoric acid, Ammonia, Fluorinert (Note 2), Galden (Note 2), Hydrofl uoric acid etc. (Note 3)(Note 1) Highly viscous liquid may not be stably detected.(Note 2) The agents mentioned above are examples. It may not be detected depending on viscosity the agent.Before using this device, check the detecting liquid and installation condition.(Note 3) Fluorinert is the world wide trademark of 3M. Galden is the registered trademark of Solvay. |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Infrared LED (modulated) |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃+14 to +131 ℉(Note) Liquid being detected should be also kept within the rated ambient temperature range. |
| Aktueller Verbrauch | 30 mA or less |
| Nutzungskategorie | DC-12, DC-13 |
| Erkennungsausgabe (Leckageerkennung) | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: Same as the supply voltage (between detection output and +V)- Residual voltage: 2.5 V or less (at 50 mA source current) |
| Hilfsausgang für die Detektion (Initialerkennung) | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: Same as the supply voltage (between detection auxiliary output and +V)- Residual voltage: 2.5 V or less (at 50 mA source current) |
| Erkennungsausgabe (Leckageerkennung): Reaktionszeit | 10 ms or less |
| Detektionsausgang (Leckageerkennung): Ausgabefunktion | ON when normal condition or initial detection, OFF when detection leakage or wrong installation |
| Hilfsausgang für die Detektion (Ersterkennung): Reaktionszeit | 50 ms or less |
| Erkennungsausgang (Leckageerkennung): Kurzschlussschutz | Incorporated |
| Hilfsausgang für die Detektion (Initialerkennung): Ausgabefunktion | ON when normal condition, OFF when initial detection or accidental leakage |
| Hilfsausgang für die Detektion (Initialerkennung): Kurzschlussschutz | Incorporated |
Technische Spezifikationen und Leistungsdaten