Wichtige Spezifikationen
Artikel:Specifications
Kabel:6–core cabtyre cable, 5 m16.404 ftlong
Bemerkung:Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
Gewicht:Switch body (standard): 180 g approx., Actuator : 20 g approx.
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Kabel6–core cabtyre cable, 5 m16.404 ftlong
BemerkungWhere measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW
GewichtSwitch body (standard): 180 g approx., Actuator : 20 g approx.
DetailsVisible type(Low code / Standard)
ProduktNon-Contact Safety Door Switch
MaterialSwitch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT, PC
TeilenummerSG-P1020-M-N
Bruttogewicht270 g approx.
ProduktnameNon-Contact Safety Door Switch SG-P
Netzspannung24V DC+10-20% Ripple P-P 10 % or less
Ansprechzeit• For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1)
ProduktnummerSG-P1020-M-N
Verschmutzungsgrad3
Aktueller Verbrauch30 mA or less
Eingabe und Ausgabe prüfenDedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output.
Anschlusskabellänge• When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units
Anwendbare Normen: JapanJIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710
Anwendbare Normen: EuropaEN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1
Steuerausgänge (OSSD 1, OSSD 2)NPN open-collector transistor 2 outputs• Maximum sink current: 100 mA• Applied voltage: Same as the power supply voltage (NPN output: between control output and 0 V)• Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable)• Leakage current: 0.2 mA or less (including power OFF state)• Maximum load capacity: 0.47 μF• Load wiring resistance: 3 Ω or less
Betriebsabstand: Vorne / SeiteSao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in
Anwendbare Normen: NordamerikaCAN/CSA C22.2 No.14, UL508
Anzahl der in Reihe geschalteten Einheiten30 units or less (standard 1 unit, sub 29 units)
Steuerausgang (OSSD): SchutzschaltungIncorporated
Anwendbare Vorschriften und ZertifizierungenCE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use.
Umweltbeständigkeit: Umgebungsfeuchtigkeit30 to 85 % RH, storage: 30 to 95 % RH
Umweltbeständigkeit: Stoßfestigkeit300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction
Anwendbare Normen: Internationaler StandardISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119
Umweltbeständigkeit: Umgebungstemperatur-10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉
Umweltbeständigkeit: SchutzgradIP65(IEC)
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions
Umweltbeständigkeit: Isolationswiderstand20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Steuerausgänge (OSSD 1, OSSD 2): Betriebsmodus• When the actuator is detected (safe state): ON• When the actuator is not detected (unsafe state or lockout state): OFF• When the switch body (sub) does not detect actuator (series connection): OFF
Umweltbeständigkeit: Spannungsfestigkeit1,000 V AC for one minute between all supply terminals connected together and enclosure

Produktbeschreibung

SG-P1020-M-N_Non-Contact Safety Door Switch_Non-Contact Safety Door Switch SG-P_Visible type(Low code / Standard)
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top