| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 4–core cabtyre cable, 3 m9.843 ftlong |
| Bemerkung | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃+73 ℉.■Transponder specificationsOperating frequency: 125 kHzMax. transmitter output: 3.33 μW |
| Gewicht | Switch body (sub): 110 g approx., Actuator: 10 g approx. |
| Details | Compact type(Low code / Sub) |
| Produkt | Non-Contact Safety Door Switch |
| Material | Switch body: PBT, PC, SUS (stainless steel), EPDMActuator: PBT |
| Teilenummer | SG-P1010-S |
| Bruttogewicht | 190 g approx. |
| Produktname | Non-Contact Safety Door Switch SG-P |
| Netzspannung | 24V DC+10-20% Ripple P-P 10 % or less |
| Ansprechzeit | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less• For multiple units: Time for single unit + 5 ms x (number of connected units - 1) |
| Produktnummer | SG-P1010-S |
| Verschmutzungsgrad | 3 |
| Aktueller Verbrauch | 20 mA or less |
| Eingabe und Ausgabe prüfen | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note)* It is not for external input and output. (voltage range 0 V to 5 V DC)(Note) : When using the device as a single unit, connect the check input with the check output. |
| Anschlusskabellänge | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit• When connecting multiple units in series: Maximum total cable length of 100 m328.084 ft, maximum cable length of 20 m65.617 ftbetween two adjacent units |
| Anwendbare Normen: Japan | JIS B 9705-1, JIS C 0508-1 to 3 (SIL3), JIS B 9961, JIS C 8201-5-2, JIS B 9710 |
| Anwendbare Normen: Europa | EN ISO 13849-1 : 2015 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 |
| Steuerausgänge (OSSD 1, OSSD 2) | — |
| Betriebsabstand: Vorne / Seite | Sao (OFF→ON): 5 mm0.197 in, Sar (ON → OFF): 15 mm0.591 in |
| Anwendbare Normen: Nordamerika | CAN/CSA C22.2 No.14, UL508 |
| Anzahl der in Reihe geschalteten Einheiten | 30 units or less (standard 1 unit, sub 29 units) |
| Steuerausgang (OSSD): Schutzschaltung | — |
| Anwendbare Vorschriften und Zertifizierungen | CE Marking (Machinery Directive, RE Directive, RoHS Directive), UKCA Marking (Supply of Machinery (Safety) Regulations, RE Regulations, RoHS Regulations), TÜV SÜD certification, TÜV SÜD certification (U.S.A., Canada), the U.S.'s radio regulations (FCC) (Note), Canada's radio regulations (ICES-003, RSS-310) (Note), Singapore's radio regulations (IMDA certification) (Note), Thailand's radio regulations (NBTC certification) (Note), Philippines' radio regulations (NTC certification) (Note), Korea's radio regulations (KC certification) (Note), India's radio regulations (WPC certification) (Note)(Note) : This product uses a weak radio signal for its detection operation. Please confirm compliance with applicable laws in the country of use. |
| Umweltbeständigkeit: Umgebungsfeuchtigkeit | 30 to 85 % RH, storage: 30 to 95 % RH |
| Umweltbeständigkeit: Stoßfestigkeit | 300 m/s2(approx. 30 G), 3 times each in X, Y, and Z direction |
| Anwendbare Normen: Internationaler Standard | ISO 13849-1 : 2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 |
| Umweltbeständigkeit: Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Umweltbeständigkeit: Schutzgrad | IP65(IEC) |
| Umweltbeständigkeit: Vibrationsbeständigkeit | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions |
| Umweltbeständigkeit: Isolationswiderstand | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Steuerausgänge (OSSD 1, OSSD 2): Betriebsmodus | — |
| Umweltbeständigkeit: Spannungsfestigkeit | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung