| Parameter | Wert |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| d.h. | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Artikel | Specifications |
| Kabel | UL style 2464, No.22 AWG 12-core |
| Gewicht | Approx. 700 g |
| Produkt | Safety door switch with key |
| Material | Enclosure : PA66 |
| Schutz | IP 65 (IEC 60529) |
| Teilenummer | SG-B2-K2AD-L5 |
| Kabellänge | 5m16.404 ft |
| Produktname | Safety door switch with key SG-B2 |
| Produktnummer | SG-B2-K2AD-L5 |
| Verriegelungskraft | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Stoßfestigkeit | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Kontaktwiderstand | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Kontaktvereinbarung | |
| Betriebsfrequenz | 900 operations/hour |
| Anwendbare Standards | EN 60947-5-1, GS-ET-19 |
| Direkte Öffnungskraft | 80 N min. |
| Schlüsselentfernungsposition | A(removable in all positions) |
| Vibrationsfestigkeit | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Direkte Öffnungsreise | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| Elektrische Haltbarkeit | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| Mechanische Haltbarkeit | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| Thermischer Strom (Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| Anwendbare Vorschriften | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Induktive Last (AC-15) | - |
| Induktive Last (DC-13) | 2.3A |
| Aktuator-Betriebsgeschwindigkeit | 0.05 to 1.0 m/sec. |
| Legende: Direkte Öffnungskraft | 0.6 N・m min. |
| Legende: Zugfestigkeit | 1.0 N・m min. |
| Legende: Direkter Öffnungsgrad | 60°min. |
| Schlüssel: Mechanische Haltbarkeit | 100,000 operations min. |
| Bemessungsisolationsspannung (Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| Schlüssel: Wichtigste Betriebsbeständigkeit | 10,000 operations min. |
| Legende: Betriebsspezifikationen | 2 positions |
| Betriebsbedingung: Höhe | 2,000 m6,561.68 ftmax. |
| Schutzklasse gegen elektrischen Schlag | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Kurzschlussschutzvorrichtung | Use 250 V / 10 A fast acting type fuse |
| Impulsspannungsfestigkeit (Uimp) | 2.5 kV |
| Bedingter Kurzschlussstrom | 50 A (250 V) |
| Betriebsbedingungen: Umgebungsfeuchtigkeit | 45 to 85 % RH |
| Betriebsbedingungen: Verschmutzungsgrad | 3 (Inside 2) |
| Anwendbare Normen: Normen für die Verwendung | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Betriebsbedingung: Umgebungstemperatur | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Bemessungsbetriebsspannung (Ue) / Bemessungsbetriebsstrom (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung