| Parameter | Wert |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| d.h. | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Artikel | Specifications |
| Kabel | UL style 2464, No.22 AWG 12-core |
| Gewicht | Approx. 600 g |
| Details | Spring lock type |
| Produkt | Ultra-slim Safety door switch with solenoid interlock |
| Material | Enclosure : PA66 |
| Schutz | IP 67 (IEC 60529) |
| Teilenummer | SG-B1-SB-G5 |
| Kabellänge | 5m16.404 ft |
| Produktname | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Hauptansprechpartner | 1NC + 1NC |
| Produktnummer | SG-B1-SB-G5 |
| Verriegelungskraft | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Stoßfestigkeit | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Kontaktwiderstand | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Betriebsfrequenz | 900 operations/hour |
| Anwendbare Standards | EN 60947-5-1, GS-ET-19 |
| Direkte Öffnungskraft | 60 N min. |
| Türüberwachungsschaltung | AC |
| Vibrationsfestigkeit | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Direkte Öffnungsreise | 8 mm0.315 inmin. |
| Türüberwachungskontakte | 2NC |
| Elektrische Haltbarkeit | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Sperrmonitorkontakte | 1NO |
| Mechanische Haltbarkeit | 1,000,000 operations min. (GS-ET-19) |
| Thermischer Strom (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Anwendbare Vorschriften | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Induktive Last (AC-15) | - |
| Induktive Last (DC-13) | 1A |
| Aktuator-Betriebsgeschwindigkeit | 0.05 to 1.0 m/sec. |
| Bemessungsisolationsspannung (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Betriebsbedingung: Höhe | 2,000 m6,561.68 ftmax. |
| Schutzklasse gegen elektrischen Schlag | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Kurzschlussschutzvorrichtung | Use 250 V / 10 A fast acting type fuse |
| Impulsspannungsfestigkeit (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Magnetventil / Anzeige: Anzeige | Green LED |
| Magnetventil / Anzeige: Nennstrom | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Betriebsbedingungen: Umgebungsfeuchtigkeit | 45 to 85 % RH |
| Betriebsbedingungen: Verschmutzungsgrad | 3 (Inside 2) |
| Magnetventil/Anzeige: Einschaltspannung | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Magnetventil/Anzeige: Abschaltspannung | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Anwendbare Normen: Normen für die Verwendung | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Betriebsbedingung: Umgebungstemperatur | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Magnetventil / Anzeige: Nennbetriebsspannung | DC 24 V 100% duty cycle |
| Bemessungsbetriebsspannung (Ue) / Bemessungsbetriebsstrom (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Technische Spezifikationen und Leistungsdaten