Servicezeiten: Montag bis Freitag 9:00-18:00
USGB1SBG1 - USGB1SBG1 SG-B1-SB-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 1m cab..
Vorrätig Top‑Produkt

USGB1SBG1

USGB1SBG1 SG-B1-SB-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 1m cab..

$0.00USD
3079 auf Lager
Wichtige Spezifikationen
:Ue
DC:Resistive load (DC-12)
d.h.:Main circuit, look monitor circuit
B10D:2,000,000(ISO 13849-1 Annex C Table C.1)
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
Ue
DCResistive load (DC-12)
d.h.Main circuit, look monitor circuit
B10D2,000,000(ISO 13849-1 Annex C Table C.1)
ArtikelSpecifications
KabelUL style 2464, No.22 AWG 12-core
GewichtApprox. 220 g
DetailsSpring lock type
ProduktUltra-slim Safety door switch with solenoid interlock
MaterialEnclosure : PA66
SchutzIP 67 (IEC 60529)
TeilenummerSG-B1-SB-G1
Kabellänge1m3.281 ft
ProduktnameUltra-slim Safety door switch with solenoid interlock SG-B1
Hauptansprechpartner1NC + 1NC
ProduktnummerSG-B1-SB-G1
Verriegelungskraft500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
StoßfestigkeitMalfunction : 100 m/s2, Destruction : 1,000 m/s2
Kontaktwiderstand300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable)
Betriebsfrequenz900 operations/hour
Anwendbare StandardsEN 60947-5-1, GS-ET-19
Direkte Öffnungskraft60 N min.
TürüberwachungsschaltungAC
VibrationsfestigkeitMalfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in
Direkte Öffnungsreise8 mm0.315 inmin.
Türüberwachungskontakte2NC
Elektrische Haltbarkeit100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load)
Sperrmonitorkontakte1NO
Mechanische Haltbarkeit1,000,000 operations min. (GS-ET-19)
Thermischer Strom (Ith)・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits)
Anwendbare VorschriftenCE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Induktive Last (AC-15)-
Induktive Last (DC-13)1A
Aktuator-Betriebsgeschwindigkeit0.05 to 1.0 m/sec.
Bemessungsisolationsspannung (Ui)300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit)
Betriebsbedingung: Höhe2,000 m6,561.68 ftmax.
Schutzklasse gegen elektrischen SchlagClass II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
KurzschlussschutzvorrichtungUse 250 V / 10 A fast acting type fuse
Impulsspannungsfestigkeit (Uimp)2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit)
Magnetventil / Anzeige: AnzeigeGreen LED
Magnetventil / Anzeige: Nennstrom110 mA (solenoid 100 mA, LED 10 mA : initial value)
Betriebsbedingungen: Umgebungsfeuchtigkeit45 to 85 % RH
Betriebsbedingungen: Verschmutzungsgrad3 (Inside 2)
Magnetventil/Anzeige: EinschaltspannungRated voltage × 85 % max. (at 20 ℃68 ℉)
Magnetventil/Anzeige: AbschaltspannungRated voltage × 10 % min. (at 20 ℃68 ℉)
Anwendbare Normen: Normen für die VerwendungIEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Betriebsbedingung: Umgebungstemperatur-25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉
Magnetventil / Anzeige: NennbetriebsspannungDC 24 V 100% duty cycle
Bemessungsbetriebsspannung (Ue) / Bemessungsbetriebsstrom (Ie)Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A

Produktbeschreibung

Safety limit switch (Ultra-narrow) for door with magnetic interconnection, spring lock, 1m cable, main 1NC+1NC, Monitor 2NC+1NO
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top