| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| PFHD | 4.06 × 10-9 |
| Kabel | 0.15mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable, 5 m16.404 ftlong |
| MTTFD | 100 years or more |
| Details | Min. sensing object ø14 mmø0.551 intype (10 mm0.394 inbeam pitch) [Cable type] |
| Produkt | Ultra-slim Safety Light Curtain [Type 4 PLe SIL3] |
| Material | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloy |
| Balkenneigung | 10 mm0.394 in |
| Zubehör | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR14 (Test rod): 1 No. |
| Teilenummer | SF4C-F47 |
| Produktname | Ultra-slim Safety Light Curtain Type 4 PLe SIL3 SF4C |
| ELCA-Funktion | Incorporated (reducing mutual interference automatically) |
| Netzspannung | 24 V DC +10-15 % Ripple P-P 10 % or less |
| Ansprechzeit | OFF response: 9 ms or lessON response: 90 ms or less |
| Produktnummer | SF4C-F47 |
| Kabelverlängerung | Extension up to 40.5 m132.874 ftis possible for both emitter and receiver, with 0.2 mm2or more cable.(Note) When the muting lamp is used, the cable can be extended within 30.5 m100.066 ft(for emitter / receiver). |
| Stummschaltungsfunktion | Incorporated |
| Betriebsbereich | 0.1 to 3 m0.328 to 9.843 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Emitterelement | Infrared LED (Peak emission wavelength: 855 nm0.034 mil) |
| Verschmutzungsgrad | 3 |
| Überschreiben-Funktion | Incorporated |
| Schutzhöhe | 480 mm18.898 in |
| Verriegelungsfunktion | Incorporated [Manual reset / Automatic reset (Note)](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Betriebshöhe | 2,000 m6,561 68 ftor less (Note:Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.) |
| Optionale Funktionen | Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting(Note) In case of using optional function, the handy-controller SFC-HC is required. |
| Umgebungsbeleuchtungsstärke | Incandescent light: 5,000 lx or less at the light-receiving face |
| Mindestens Erfassungsobjekt | ø14 mmø0.551 inopaque object(Note) When the floating blanking function is used, the size of the min. sensing object is changed. |
| Anzahl der Strahlkanäle | 47 |
| Sicherheitseingangsfunktion | Incorporated (safety contact) |
| Effektiver Öffnungswinkel | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] |
| Anwendbare Normen: Japan | JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3(SIL3) |
| Anwendbare Normen: Europa | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL 3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Test-/Reset-Eingangsfunktion | Incorporated |
| Steuerausgänge (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 200 mA- Applied voltage: same as supply voltage (between the control output and +V)- Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less[When selecting NPN output]- Max. sink current: 200 mA- Applied voltage: same as supply voltage (between the control output and 0 V)- Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m32.808 ftlength cable)- Leakage current: 200 micro A or less (including power supply OFF condition)- Max. load capacity: 1 micro F (No load to Max. output current)- Load wiring resistance: 3 Ω or less |
| Anwendbare Normen: Nordamerika | ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14,OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Funktion zur Überwachung externer Geräte | Incorporated |
| Hilfsausgang (Nicht-Sicherheitsausgang) | PNP open-collector transistor / NPN open-collector transistor (switching method)[When selecting PNP output]- Max. source current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and +V)- Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m32.808 ftlength cable)[When selecting NPN output]- Max. sink current: 100 mA- Applied voltage: same as supply voltage (between the auxiliary output and 0 V)- Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m32.808 ftlength cable) |
| Anwendbare Vorschriften und Zertifizierungen | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Umweltbeständigkeit: Umgebungsfeuchtigkeit | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Umweltbeständigkeit: Stoßfestigkeit | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Nettogewicht (Gesamtgewicht von Sender und Empfänger) | 860 g approx. |
| Anwendbare Normen: Internationaler Standard | IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL 3) |
| Umweltbeständigkeit: Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉ |
| Umweltbeständigkeit: Schutzgrad | IP67 / IP65 (IEC) |
| Umweltbeständigkeit: Vibrationsbeständigkeit | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Umweltbeständigkeit: Isolationswiderstand | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Steuerausgänge (OSSD 1, OSSD 2): Betriebsmodus | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the Safety Light Curtain or the synchronization signal)(Note) The outputs are not ''OFF'' when muting function is active even if the beam channel is interruped.(Note) In case the blanking function is valid, the operation mode is changed. |
| Steuerausgänge (OSSD1, OSSD2): Schutzschaltung | Incorporated |
| Umweltbeständigkeit: Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Hilfsausgang (Nicht-Sicherheitsausgang): Betriebsmodus | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFC-HC handy-controller). |
| Hilfsausgang (Nicht-Sicherheitsausgang): Schutzschaltung | Incorporated |
| Aktueller Verbrauch: Große Mehrzweckanzeige leuchtet auf | Emitter: 115 mA or lessReceiver: 120 mA or less |
| Aktueller Verbrauch: Große Mehrzweck-Anzeigeleuchten aus | Emitter: 80 mA or lessReceiver: 90 mA or less |
Technische Spezifikationen und Leistungsdaten