Servicezeiten: Montag bis Freitag 9:00-18:00
USF4BH36CAJ05 - USF4BH36CAJ05 SF4B-H36CA-J05 PANASONIC Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective hei..
Vorrätig Top‑Produkt

USF4BH36CAJ05

USF4BH36CAJ05 SF4B-H36CA-J05 PANASONIC Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective hei..

$0.00USD
4467 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
PFHD:3.3 × 10-9(Note) Probability of dangerous failure per hour.
Kabel:0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD:100 years or more(Note) Mean time to dangerous failure.
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
PFHD3.3 × 10-9(Note) Probability of dangerous failure per hour.
Kabel0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long
MTTFD100 years or more(Note) Mean time to dangerous failure.
DetailsMin. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
ProduktCompact Safety Light Curtain[Type4 PLe SIL3]
MaterialEnclosure: Polycarbonate
Balkenneigung20 mm0.787 in
ZubehörSF4B-TR25 (Test rod): 1 pc.
TeilenummerSF4B-H36CA-J05
ProduktnameCompact Safety Light Curtain[Type4 PLe SIL3] SF4B-C
ELCA-FunktionIncorporated (reducing mutual interference automatically)
Netzspannung24 V DC plus or minus 10 % Ripple P-P 10 % or less
AnsprechzeitOFF response: 14 ms or lessON response: 80 to 90 ms
ProduktnummerSF4B-H36CA-J05
KabelverlängerungExtension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables
StummschaltungsfunktionIncorporated
Betriebsbereich0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver.
EmitterelementInfrared LED (Peak emission wavelength: 850 nm0.033 mil)
Verschmutzungsgrad3
Überschreiben-FunktionIncorporated
Schutzhöhe743.4 mm 29.268 in
VerriegelungsfunktionIncorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status.
Betriebshöhe2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m.
Optionale FunktionenMuting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required.
UmgebungsbeleuchtungsstärkeIncandescent light: 3,500 liter x or less at the light-receiving face
Mindestens Erfassungsobjektø25 mm ø0.984 in opaque object(Note) In case the blanking function is valid, the operation mode is changed.
Anzahl der Strahlkanäle36
EmissionsstoppfunktionIncorporated
Hilfsausgang stummschaltenNPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable)
Effektiver Öffnungswinkelplus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ]
Anwendbare Normen: JapanJIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3)
Anwendbare Normen: EuropaEN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
Steuerausgänge (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less
Anwendbare Normen: NordamerikaANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark.
Funktion zur Überwachung externer GeräteIncorporated
Hilfsausgang (Nicht-Sicherheitsausgang)PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable)
Große Mehrzweck-AnzeigefunktionIncorporated
Stummschaltung des Hilfsausgangs: BetriebsmodusWhen muting auxiliary output: ON
Anwendbare Vorschriften und ZertifizierungenCE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification
Umweltbeständigkeit: Umgebungsfeuchtigkeit30 to 85 % RH, Storage: 30 to 85 % RH
Umweltbeständigkeit: Stoßfestigkeit300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each
Stummschaltung des Hilfsausgangs: SchutzschaltungIncorporated
Nettogewicht (Gesamtgewicht von Sender und Empfänger)approx. 840 g
Anwendbare Normen: Internationaler StandardIEC 61496-1 / 2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3)
Umweltbeständigkeit: Umgebungstemperatur-10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉
Umweltbeständigkeit: SchutzgradIP65 (IEC)
Umweltbeständigkeit: Vibrationsbeständigkeit10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each
Umweltbeständigkeit: Isolationswiderstand20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure
Steuerausgänge (OSSD 1, OSSD 2): BetriebsmodusON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change.
Steuerausgänge (OSSD1, OSSD2): SchutzschaltungIncorporated
Umweltbeständigkeit: Spannungsfestigkeit1,000 V AC for one min. between all supply terminals connected together and enclosure
Hilfsausgang (Nicht-Sicherheitsausgang): BetriebsmodusOFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.)
Hilfsausgang (Nicht-Sicherheitsausgang): SchutzschaltungIncorporated
Aktueller Verbrauch: Große Mehrzweckanzeige leuchtet aufEmitter: 85 mA or lessReceiver: 105 mA or less
Aktueller Verbrauch: Große Mehrzweck-Anzeigeleuchten ausEmitter: 75 mA or lessReceiver: 95 mA or less

Produktbeschreibung

SF4B-C Cat.4 Safety Barrier (PLe SIL3), 20 mm hand-to-beam protection, protected height 743.4 mm, operating range 0.3 to 7m, PNP/NPN, connector, IP65, muting function
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top