| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| PFHD | 3.74 × 10-9(Note) Probability of dangerous failure per hour. |
| Kabel | 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Details | Hand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch) |
| Produkt | Ultra-slim Light Curtain [Type 2 PLc SIL1] |
| Material | Enclosure: Polycarbonate alloySensing surface: Polycarbonate alloyMS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
| Balkenneigung | 20 mm0.787 in |
| Zubehör | MS-SFC-1 (Standard mounting bracket): 1 setSF4C-TR25 (Test rod): 1 No. |
| Teilenummer | SF2C-H8-N |
| Produktname | Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C |
| Netzspannung | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
| Ansprechzeit | OFF response: 20 ms or lessON response: 80 to 100 ms |
| Produktnummer | SF2C-H8-N |
| Kabelverlängerung | Extension up to total 50m is possible for 0.3mm2or more, cable |
| Betriebsbereich | 0.1 to 3 m0.328 to 9.843 ft |
| Emitterelement | Infrared LED (Peak emission wavelength: 850 nm0.034 mil) |
| Verschmutzungsgrad | 3 |
| Schutzhöhe | 160 mm6.299 in |
| Betriebshöhe | 2, 000 m6561.680 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Umgebungsbeleuchtungsstärke | Incandescent light: 5,000 ℓx or less at the light-receiving face |
| Sperrausgang (SSD) | - Maximum sink current: 60mA- Applied voltage: same as supply voltage (between the lockout output and -0V)- Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Mindestens Erfassungsobjekt | ø25 mmø0.984 inopaque object |
| Testeingabefunktion | Incorporated |
| Steuerausgang (OSSD) | - Maximum sink current: 200mA- Applied voltage: same as supply voltage (between the control output and -0V)- Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable)- Leakage current: 200micro A or less (power supply OFF condition)- Maximum load capacity: 2.2micro F (No load to maximum output current)- Load wiring resistance: 3Ω or less |
| Anzahl der Strahlkanäle | 8 |
| Effektiver Öffnungswinkel | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Anwendbare Normen: Japan | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508-1 to 3 (SIL 1) |
| Anwendbare Normen: Europa | EN 61496-1 (Type 2), EN ISO 13849-1:2015 (Category 2, PLc), EN 61508-1 to 3 (SIL 1), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Störungsverhinderungsfunktion | Incorporated |
| Anwendbare Normen: Nordamerika | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| Sperrausgang (SSD): Betriebsmodus | ON during normal operation, OFF during lockout(Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
| Steuerausgang (OSSD): Betriebsmodus | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
| Große Mehrzweck-Anzeigefunktion | Incorporated |
| Sperrausgang (SSD): Schutzschaltung | Incorporated |
| Steuerausgang (OSSD): Schutzschaltung | Incorporated |
| Anwendbare Vorschriften und Zertifizierungen | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| Umweltbeständigkeit: Umgebungsfeuchtigkeit | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Umweltbeständigkeit: Stoßfestigkeit | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Nettogewicht (Gesamtgewicht von Sender und Empfänger) | 280 g approx. |
| Anwendbare Normen: Internationaler Standard | IEC 61496-1 / 2 (Type 2), ISO 13849-1:2015 (Category 2, PLc), IEC 61508-1 to 3 (SIL 1) |
| Umweltbeständigkeit: Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉ |
| Umweltbeständigkeit: Schutzgrad | IP65, IP67 (IEC) |
| Umweltbeständigkeit: Vibrationsbeständigkeit | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Umweltbeständigkeit: Isolationswiderstand | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Umweltbeständigkeit: Spannungsfestigkeit | 1, 000 V AC for one min. between all supply terminals connected together and enclosure |
| Aktueller Verbrauch: Große Mehrzweckanzeige leuchtet auf | Emitter: 35 mA or lessReceiver: 30 mA or less |
| Aktueller Verbrauch: Große Mehrzweck-Anzeigeleuchten aus | Emitter: 25 mA or lessReceiver: 25 mA or less |
Technische Spezifikationen und Leistungsdaten