Servicezeiten: Montag bis Freitag 9:00-18:00
UFX505C2 - UFX505C2 FX-505-C2 PANASONIC Fiber amplifier, NPN, analogue output, double display
Vorrätig Top‑Produkt

UFX505C2

UFX505C2 FX-505-C2 PANASONIC Fiber amplifier, NPN, analogue output, double display

$0.00USD
4554 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Kabel:0.2 mm26-core cabtyre cable, 2 m6.562 ftlong
Gewicht:Net weight: 60 g approx.Gross weight: 100 g approx.
Details:Cable type
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Kabel0.2 mm26-core cabtyre cable, 2 m6.562 ftlong
GewichtNet weight: 60 g approx.Gross weight: 100 g approx.
DetailsCable type
ProduktDigital Fiber Sensor
MaterialEnclosure, Case cover: PolycarbonateSwitch: Polyacetal
ZubehörFX-MB1 (Amplifier protection seal): 1 set
SchutzIP40 (IEC)
TeilenummerFX-505-C2
ProduktnameDigital Fiber Sensor FX-500 Ver.2
AnalogausgangOutput current: 4 to 20 mA approx. [H-SP, FAST STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note) ]Response time: 2 ms or lessZero point: Within 4 mA plus or minus 1 % F.S.Span: Within 16 mA plus or minus 5 % F.S.Linearity: Within plus or minus 3 % F.S.Load resistance: 0 to 250 Ohm(Note) If display adjustment was conducted, it is not in this range.
AnsprechzeitH-SP: 25 micro s or lessFAST: 60 micro s or lessSTD: 250 micro s or lessLONG: 2 ms or lessU-LG: 4 ms or lessHYPR: 24 ms or less, selectable
Externer EingangNPN non-contact input- Signal conditionHigh: +8 V to +V DC or OpenLow: 0 to +1.2 V DC(at 0.5 mA source current)- Input impedance: 10 kOhm approx.
ProduktnummerFX-505-C2
Versorgungsspannung12 to 24 V DC+10-15 % Ripple P-P 10 % or less
TimerfunktionIncorporated with variable OFF-delay / ON-delay /One-shot / ON-delay - OFF-delay / ON-delay - One-shot timer, switchable either effective or ineffectiveIncorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either effective or ineffective
KabelverlängerungExtension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. (however, supply voltage 12 V DC or more)
Verschiedene EinstellungenHysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold value tracking setting, etc.
StromverbrauchNormal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output)ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output)
Ausgang 1, Ausgang 2NPN open-collector transistor- Maximum sink current: 50 mA (Note 1)- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (Note 2) (at maximum sink current)(Note 1) 50 mA max. if 5 or more standard types are connected together.(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)
Umgebungstemperatur-10 to +55 ℉+14 to +131 ℉[If 4 to 7 units are mounted in cascade: -10 to +50 ℉+14 to +122 ℉or if 8 to 12 units are mounted in cascade: -10 to +45 ℉+14 to +113 ℉] (No dew condensation or icing allowed), Storage: -20 to +70 ℉-4 to +158 ℉
Empfindlichkeitseinstellung2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Timerfunktion: TimerperiodeTimer range ''ms'': 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.Timer range ''sec.'': 0.5 s approx., 1 to 32 s approx., 1 s approx.Timer range ''1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx.each output is set individually
Emitter (moduliert)Red LED (Peak emission wavelength: 643 nm0.025 mil)
Einhaltung der CE-KennzeichnungsrichtlinieEMC Directive, RoHS Directive
Funktion zur Einstellung der EmissionsmengeIncorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]
StörungsverhinderungsfunktionIncorporated (Note) , selectable either automatic interference prevention or different frequency(Note) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.- Number of sensor heads mountable closely (Unit: set)Response time: IP-1H-SP: 0FAST: 2STD: 4LONG: 8U-LG: 8HYPR: 12
Ausgang 1, Ausgang 2: Ausgabepunkte2 points
Mögliche externe EingangsfunktionEmission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy lock / Display adjustment / Data bank load / Data bank save, selectable
Ausgang 1, Ausgang 2: AusgabevorgangSwitchable either Light-ON or Dark-ON by L/D mode
Anzeigebereich der einfallenden LichtintensitätH-SP / FAST / STD: 0 to 4,000LONG: 0 to 8,000U-LG / HYPR: 0 to 9,999
Externer Eingang (umschaltbar mit Ausgang 2)-
Ausgang 1, Ausgang 2: KurzschlussschutzIncorporated

Produktbeschreibung

FX-500 F Amplifier. Optical, analog output, 2 NPN outputs, dual display, high sensitivity and detection distance, ultra-fast
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top