| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Ausgabe | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Details | Retroreflective type |
| Produkt | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Zubehör | RF-330 (Reflector): 1 pc.MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysterese | 20 % or less of operation distance |
| Schutz | IP67 (IEC) |
| Teilenummer | EX-L291-P-J |
| Produktname | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Wiederholbarkeit | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Ansprechzeit | 0.5 ms or less |
| Erfassungsbereich | 4 m13.123 ft(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Produktnummer | EX-L291-P-J |
| Erfassungsobjekt | Opaque translucent object of ø25 mmø0.984 inor more |
| Versorgungsspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 0.5 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 lx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Aktueller Verbrauch | 15 mA or less |
| Empfindlichkeitsregler | Continuously variable adjuster |
| Vibrationsfestigkeit | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Einhaltung gesetzlicher Bestimmungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Ausgabe: Ausgabeoperation | Light-ON / Dark-ON selectable by the output operation switching input |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emissionsfleckgröße (typisch) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical x horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 4 m 13.123 ft, the emission spot size is H 18 x W 10 mmH 0.709 x W 0.394 in(visual reference value). |
| Ausgang: Kurzschlussschutz | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimales Erfassungsobjekt (typisch) | - |
| Automatische Störungsverhinderungsfunktion | Incorporated(Two sensors can be mounted close together.) |
| Wiederholgenauigkeit (typisch) (senkrecht zur Messachse) | - |