| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Ausgabe | PNP open-collector transistor- Maximum source current: 50 mA |
| Details | Convergent reflective type |
| Produkt | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Zubehör | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysterese | 20 % or less of operation distance |
| Schutz | IP67(IEC) |
| Teilenummer | EX-L261-P-J |
| Produktname | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Wiederholbarkeit | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Ansprechzeit | 0.5 ms or less |
| Erfassungsbereich | 20 to 50 mm0.787 to 1.969 in(Convergent point: 22 mm0.866 in)(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Produktnummer | EX-L261-P-J |
| Erfassungsobjekt | Opaque, translucent or transparent object(Note)Make sure to confirm detection with an actual sensor before use. |
| Versorgungsspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Umgebungsfeuchtigkeit | 35 to 85%RH , Storage: 35 to 85%RH |
| Emitterelement | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS)(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)(Maximum output: 1 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Aktueller Verbrauch | 15 mA or less |
| Empfindlichkeitsregler | Continuously variable adjuster |
| Einhaltung gesetzlicher Bestimmungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Ausgabe: Ausgabeoperation | Light-ON / Dark-ON selectable by the output operation switching input |
| Emissionsfleckgröße (typisch) | dia. 1mm 0.039 in(at a sensing distance of 50 mm 1.969 in) |
| Ausgang: Kurzschlussschutz | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimales Erfassungsobjekt (typisch) | Gold wire of ø0.01 mmø0.0004 in(Note) Typical values when the sensitivity adjuster is optimally adjusted. |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung