| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Ausgabe | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 26.4 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) |
| Details | Spot reflective type |
| Produkt | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Zubehör | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysterese | 20 % or less of operation distance |
| Schutz | IP67 (IEC) |
| Teilenummer | EX-L221-P-J |
| Produktname | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Wiederholbarkeit | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Ansprechzeit | 0.5 ms or less |
| Erfassungsbereich | 45 to 300 mm1.772 to 11.811 in(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Produktnummer | EX-L221-P-J |
| Erfassungsobjekt | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Versorgungsspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB/ EN/ KS) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 2 mW, Peak emission wavelength: 655 nm0.026 mil) |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 lx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Aktueller Verbrauch | 15 mA or less |
| Empfindlichkeitsregler | Continuously variable adjuster |
| Vibrationsfestigkeit | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Einhaltung gesetzlicher Bestimmungen | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Ausgabe: Ausgabeoperation | Light-ON / Dark-ON selectable by the output operation switching input |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emissionsfleckgröße (typisch) | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Ausgang: Kurzschlussschutz | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimales Erfassungsobjekt (typisch) | Gold wire of ø0.01 mmø0.0004 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Automatische Störungsverhinderungsfunktion | Incorporated(Two sensors can be mounted close together.) |
| Wiederholgenauigkeit (typisch) (senkrecht zur Messachse) | 0.02 mm0.0008 inor less(at 100 to 200 mm sensing distance)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung