| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.1 mm2 3-core cabtyre cable, 1 m 3.281 ft long |
| Ausgabe | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Gewicht | Net weight: 15 g approx., Gross weight: 60 g approx. |
| Details | Amplifier built-in, Pipe-mountable |
| Produkt | Pipe-mountable Liquid Level Detection Sensor |
| Material | Enclosure: Polycarbonate, Tying band: Nylon, Anti-slip tube: Silicone |
| Zubehör | Tying band: 2 pcs., Anti-slip tube: 2 pcs. |
| Teilenummer | EX-F1 |
| Produktname | Pipe-mountable Liquid Level Detection Sensor EX-F1 |
| Ansprechzeit | 2 ms or less |
| Produktnummer | EX-F1 |
| Erfassungsobjekt | Liquid(Note):Unclear or highly viscous liquid may not be detected stably. |
| Versorgungsspannung | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| Kabelverlängerung | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Infrared LED (modulated) |
| Stoßfestigkeit | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Umgebungsbeleuchtungsstärke | lncandescent light: 3,000 lx or less at the light-receiving face |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃-4 to +158 ℉(Note:Liquid being detected should also be kept within the rated ambient temperature range.) |
| Aktueller Verbrauch | 30 mA or less(Note:Unclear or highly viscous liquid may not be detected stably.) |
| Betriebsanzeige | Red LED (lights up when the output is ON) |
| Vibrationsfestigkeit | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Ausgabe: Ausgabeoperation | Switchable either Light-ON (Liquid-absent-ON) or Dark-ON (Liquid-present-ON) |
| Anwendbarer Rohrdurchmesser | Outer dia. ø6 to ø13 mm ø0.236 to ø0.512 in transparent resin pipe[PFA (Fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in ](Note:Do not use the sensor with pipes other than the above specified.) |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Einhaltung der CE-Kennzeichnungsrichtlinie | EMC Directive, RoHS Directive |
| Ausgang: Kurzschlussschutz | Incorporated |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung