| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.3 mm23-core cabtyre cable, 2 m6.562 ftlong |
| Ausgabe | PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between output and + V)- Residual voltage: 1 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) |
| Gewicht | Net weight: 150 g approxGross weight: 200 g approx |
| Details | PNP output |
| Produkt | Adjustable Range Reflective Photoelectric Sensor |
| Material | Enclosure: Polyalylate and Polyethylene terephthalateLens: Polyalylate |
| Zubehör | Adjusting screwdriver: 1 pc. |
| Hysterese | 10 % or less of operation distance (With white non-glossy paper) |
| Schutz | IP67 (IEC) |
| Teilenummer | EQ-34-PN-J |
| Produktname | Adjustable Range Reflective Photoelectric Sensor EQ-30 |
| Wiederholbarkeit | Along sensing axis: 10 mm0.394 inor less, Perpendicular to sensing axis: 1 mm0.039 inor less (with white non-glossy paper) |
| Ansprechzeit | 2 ms or less |
| Produktnummer | EQ-34-PN-J |
| Versorgungsspannung | 10 to 30 V DC Ripple P-P 10 % or less |
| Kabelverlängerung | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Einstellbereich | 0.2 to 2 m0.656 to 6.562 ft(Note) The adjustable range stands for the maximum sensing range which can be set with the adjuster.The sensor can detect an object 0.1 m0.328 ft, or more, away. |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitterelement | Infrared LED (Peak emission wavelength: 880 nm0.035 mil, modulated) |
| Verschmutzungsgrad | 3 (Industrial environment) |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Distanzversteller | 2-turn mechanical adjuster with pointer |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 ℓx or less at the light-receiving face |
| Umgebungstemperatur | -20 to +55 ℃-4 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +70 ℃-13 to +158 ℉ |
| Aktueller Verbrauch | 55 mA or less |
| Betriebsanzeige | Red LED (lights up when the output is ON) |
| Stabilitätsindikator | Green LED (lights up under stable light received condition or stable dark condition) |
| Vibrationsfestigkeit | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 250 V megger between all supply terminals connected together and enclosure |
| Ausgabe: Ausgabeoperation | Switchable either Detection-ON or Detection-OFF |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Ausgabe: Nutzungskategorie | DC-12 or DC-13 |
| Einhaltung der CE-Kennzeichnungsrichtlinie | EMC Directive, RoHS Directive |
| Ausgang: Kurzschlussschutz | Incorporated |
| Automatische Störungsverhinderungsfunktion | Incorporated(Note) Detection may become unstable depending on the setting conditions or the sensing objects. After setting up this product, make sure to check operations using actual sensing objects. |
| Erfassungsbereich (mit weißem, mattem Papier bei einem Einstellabstand von 2 m 6,562 ft) | 0.1 to 2 m0.328 to 6.562 ft |