| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.2 mm26-core cabtyre cable, 2 m 6.562 ft long |
| Gewicht | Net weight: 65 g approx., Gross weight: 110 g approx. |
| Details | Controller |
| Produkt | Electrostatic Sensor |
| Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS |
| Linearität | plus or minus0.5 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be equal to the displayed values plus or minus5 %.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Teilenummer | EF-S1C |
| Produktname | Electrostatic Sensor EF-S1 |
| Analogausgang | Analog voltage• Output voltage: 1 to 5 V• Output impedance: 100 Ohm approx.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| Wiederholbarkeit | plus or minus0.3 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode. |
| Produktnummer | EF-S1C |
| Versorgungsspannung | 24V DC plus or minus10 % |
| Kabelverlängerung | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Umgebungstemperatur | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ – 4 to +158 ℉ |
| Aktueller Verbrauch | Normal operation: 50 mA or less, ECO mode: 40 mA or less |
| Geeigneter Sensorkopf | EF-S1HS |
| Anzeigebereich (Bereichsmodus) | –1,000 to 1,000 (plus or minus1 kV range mode)–1,999 to 1,999 (plus or minus2kV range mode)(Note) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller. |
| Analogausgang: Reaktionszeit | 20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method |
| Temperaturcharakteristik | 0.05 % F.S./℃(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values. |
| Timing-Eingang / Null-Einstelleingang | NPN non-contact input• Signal conditionHigh: +V or open,Low: 0 to +2 V (source current 0.5 mA or less)• Input impedance: 10 kOhm approx. |
| Urteilsausgaben (OUT 1, OUT 2) | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: 30 V DC or less (between judgment output and 0 V)• Residual voltage: 1.5 V or less (at 100 mA sink current) |
| CE-Kennzeichnung gemäß den Richtlinien | EMC Directive, RoHS Directive |
| Beurteilungsergebnisse (OUT 1, OUT 2): Reaktionszeit | 10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method |
| Urteilsausgänge (OUT 1, OUT 2): Ausgabeoperation | OUT1: +potential measurement output or window comparator outputOUT2: –potential measurement output or error output |
| Ausgänge für die Beurteilung (OUT 1, OUT 2): Kurzschlussschutz | Incorporated |