Servicezeiten: Montag bis Freitag 9:00-18:00
UDP102ZL3MP - UDP102ZL3MP DP-102ZL3-M-P PANASONIC Pressure sensor, -1 to 10bar, IO Link, pressure connector short M5 femal..
Vorrätig Top‑Produkt

UDP102ZL3MP

UDP102ZL3MP DP-102ZL3-M-P PANASONIC Pressure sensor, -1 to 10bar, IO Link, pressure connector short M5 femal..

$0.00USD
4126 auf Lager
Wichtige Spezifikationen
Artikel:Specifications
Bemerkung:(Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
Gewicht:Net weight: 30 g approx., Gross weight: 125 g approx.
Details:Discrete wire type
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
Bemerkung(Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
GewichtNet weight: 30 g approx., Gross weight: 125 g approx.
DetailsDiscrete wire type
Anzeige4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
ProduktDual Display Digital Pressure Sensor [For Gas]
MaterialEnclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
SchutzIP40(IEC)
ZubehörCN-14A-C2 (Connector attached cable 2 m6.562 ft): 1 pc.
TeilenummerDP-102ZL3-M-P
KabellängeTotal length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable.
ProduktnameDual Display Digital Pressure Sensor [For Gas] DP-100L
DruckanschlussM5 female thread
ProduktnummerDP-102ZL3-M-P
Versorgungsspannung12 to 24 V DC ±10 % Ripple P-P 10 % or less
Umgebungsfeuchtigkeit35 to 85 % RH, Storage: 35 to 85 % RH
Geeignete FlüssigkeitNon-corrosive gas
AusgabeanzeigeOrange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON)
Stoßfestigkeit100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
DruckartGauge pressure
VerbindungsmethodeConnector
StromverbrauchNormal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
Einstelldruckbereich-0.101 to +1.010MPa
Umgebungstemperatur-10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉
Steuerausgang (DO)PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current)
Nenndruckbereich-0.100 to +1.000 Mpa
Vibrationsfestigkeit10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Isolationswiderstand50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Spannungsfestigkeit1,000 V AC for one min. between all supply terminals connected together and enclosure
Druckbeständigkeit1.5MPa
TemperaturcharakteristikWithin ±1 % F.S.(at +20℃+68℉)
Steuerausgang (DO): HystereseMinimum 1 digit (variable)
Steuerausgang (DO): Wiederholgenauigkeit±0.2 % F.S. (within ±2 digits)
Steuerausgang (DO): Reaktionszeit2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Anzeige: Anzeigbarer Druckbereich-0.101 to +1.010MPa
Kommunikationsausgang (C/Q): BaudrateCOM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Steuerausgang (DO): AusgangsfunktionN.O./N.C. (selectable by key operation)
Kommunikationsausgabe (C/Q): Prozessdaten4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Einhaltung gesetzlicher Bestimmungen und ZertifizierungCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification
Steuerausgang (DO): KurzschlussschutzIncorporated
Kommunikationsausgang (C/Q): Minimale Zykluszeit1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Kommunikationsausgang (C/Q): IO-Link-KommunikationIO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Steuerausgang (DO): Ausgangsbetrieb, AusgangsmodiEASY mode / Hysteresis mode / Window comparator mode

Produktbeschreibung

DP-100L Series. Digital pressure controller, -1 to 10bar, short M5 female threaded pressure port, 2m cable, IO Link connection, PNP
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top