| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Bemerkung | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉. |
| Gewicht | 25 g approx. |
| Details | For gas |
| Anzeige | 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms) |
| Produkt | Digital Pressure Sensor |
| Material | Enclosure: PBT (glass fiber reinforced)LCD display: AcrylicPressure port: Brass (nickel plated)Mounting threaded part: BrassO-ring: Nitrile rubber (NBR)Key section: Polycarbonate |
| Schutz | IP40 (IEC) |
| Zubehör | CN-14A-C2 (Connector attached cable 2 m6.562 ft) : 1 pc. |
| Teilenummer | DP-002-P |
| Produktname | Digital Pressure Sensor [For Gas] DP-0 |
| Druckanschluss | M5 female thread |
| Produktnummer | DP-002-P |
| Versorgungsspannung | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Nutzbare Höhe | 2,000 m6,562 ftor less |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Geeignete Flüssigkeit | Air, non-corrosive gas |
| Erdungsmethode | Floating |
| Verschmutzungsgrad | 2 |
| Auswählbare Einheiten | MPa, kgf/cm2, bar, psi |
| Stoßfestigkeit | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Druckart | Gauge pressure |
| Stromverbrauch | 30 mA or less |
| Vergleichsausgabe | PNP open-collector transistor- Maximum source current: 50 mA- Applied voltage: 30 V DC or less (between comparative output and +V)- Residual voltage: 2 V or less (at 50 mA source current) |
| Einstelldruckbereich | -0.010 to +1.010 MPa-0.1 to +10.30 kgf/cm2-0.1 to + 10.10 bar-0.1 to +146.5 psi |
| Umgebungstemperatur | 0 to +50 ℃+32 to +122 ℉(No dew condensation allowed), Storage: -10 to +60 ℃+14 to +140 ℉ |
| Überspannungskategorie | I |
| Nenndruckbereich | 0.000 to +1.000 Mpa |
| Vibrationsfestigkeit | 10 to 150 Hz frequency, 0.75 mm double amplitude0.030 inor maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each |
| Isolationswiderstand | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
| Anwendbare Vorschriften | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Spannungsfestigkeit | 500 V AC for one min. between all supply terminals connected together and enclosure |
| Druckbeständigkeit | 1.5 MPa |
| Vergleichsausgabe: Hysterese | Minimum 2 digits (variable) |
| Vergleichsergebnis: Wiederholbarkeit | ±0.4 % F.S. (within ±4 digits) |
| Vergleichsausgabe: Reaktionszeit | 2.5 ms, 25 ms, 250 ms, selectable by key operation |
| Anzeige: Anzeigbarer Druckbereich | -0.010 to +1.010 MPa-0.1 to +10.30 kgf/cm2-0.1 to + 10.10 bar-0.1 to +146.5 psi |
| Vergleichsausgabe: Ausgabeoperation | Selectable either NO or NC by key operation |
| Temperatureigenschaften (+20℃ Standard) | +10 to +40℃+50 to +104 ℉: Within ±2 % F.S.0 to +50℃32 to +122℉: Within ±5 % F.S. |
| Vergleichsausgang: Kurzschlussschutz | Incorporated |