| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.2 mm24-core cabtyre cable, 2 m6.562 ftlong |
| Ausgabe | PNP open-collector transistor- Maximum source current: 100 mA- Applied voltage: 30 V DC or less (between output and +V)- Residual voltage: 2 V or less (at 100 mA source current), 1 V or less (at 16 mA source current) |
| Gewicht | Net weight: 55 g approx.Gross weight: 65 g approx. |
| Details | Adjustable range reflective |
| Produkt | Compact Photoelectric Sensor |
| Material | Enclosure: PBT (Polybutylene terephthalate)Front cover: PolycarbonateIndicator cover: Polycarbonate |
| Hysterese | 5 % or less of operation distance(with white non-glossy paper) |
| Schutz | IP67 (IEC) |
| Teilenummer | CX-442-P |
| Produktname | Compact Photoelectric Sensor CX-400 Ver.2 |
| Erfassungsmodus | BGS / FGS functions switchable with wiring of sensing mode selection input |
| Wiederholbarkeit | Along sensing axis: 1 mm0.039 inor less, Perpendicular to sensing axis: 0.2 mm0.008 inor less (with white non-glossy paper) |
| Ansprechzeit | 1 ms or less |
| Spotdurchmesser | Ø15 mmØ0.591 inapprox.(at 300 mm11.811 indistance) |
| Produktnummer | CX-442-P |
| Versorgungsspannung | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Kabelverlängerung | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Einstellbereich | 40 to 300 mm1.575 to11.811 in(Note) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object 2 mm0.079 in[CX-444(-P): 15 mm0.591 in, CX-442(-P): 20 mm0.787 in], or more, away. |
| Umgebungsfeuchtigkeit | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Stoßfestigkeit | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Distanzversteller | 5-turn mechanical adjuster |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,000 lx or less at the light-receiving face |
| Umgebungstemperatur | - 25 to +55℃-13 to +131℃ ℉(No dew condensation or icing allowed ), Storage: -30 to +70℃-22 to +158℃ ℉ |
| Aktueller Verbrauch | 20 mA or less |
| Betriebsanzeige | Orange LED (lights up when the output is ON) |
| Stabilitätsindikator | Green LED(lights up under stable operating condition) |
| Vibrationsfestigkeit | 10 to 500 Hz frequency, 3 mm0.118 inamplitude in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Ausgabe: Ausgabeoperation | Switchable either Detection-ON or Detection-OFF |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emitter (moduliert) | Red LED |
| Einhaltung der CE-Kennzeichnungsrichtlinie | EMC Directive, RoHS Directive |
| Ausgang: Kurzschlussschutz | Incorporated |
| Automatische Störungsverhinderungsfunktion | Incorporated(Note) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to check the operation with the actual sensing object. |
| Erfassungsbereich (mit weißem, mattem Papier) | 20 to 300 mm0.787 to11.811 in |
| Emissionselement (moduliert): Emissionswellenlänge des Maximums | 650 nm0.026 mil |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung