| Parameter | Wert |
|---|---|
| 115 V AC ... 240 V AC ±10 % (UL) | |
| Farbe | red, yellow, green (multicolor LED) |
| Tiefe | 132 mm |
| E/A/S | asymmetrical |
| Eingang | asymmetrical 2 kV (Test Level 3) |
| Breite | 55 mm |
| starr | 0.2 mm² ... 4 mm² |
| Höhe | 135 mm |
| Ausgabe | asymmetrical 2 kV (Test Level 3) |
| Signal | asymmetrical 1 kV (Test Level 3) |
| LED aus | Supply voltage input AC not present (Off) |
| Stromspannung | 10 V (Test Level 3) |
| Kommentare | Criterion B |
| Leistungsreduzierung | < 100 V AC (1 %/V) |
| Funktion | Visual operating state display |
| Position | 3.x |
| flexibel | 0.2 mm² ... 2.5 mm² |
| Frequenz | 50 Hz |
| Aufstiegszeit | ≤ 1 s (UOut= 10 % ... 90 %) |
| Temporärer Code | T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K) |
| EN 61010-1 | III (≤ 2000 m) |
| Effizienz | typ. 93.8 % (120 V AC) |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Kriterium C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Spannungseinbruch | 70 % |
| starr (AWG) | 24 ... 12 (Cu) |
| Crest-Faktor | typ. 1.77 (120 V AC) |
| Hood-Version | Polycarbonate |
| Produktart | Power supply |
| Montagehinweis | alignable: 0 mm horizontally, 30 mm vertically |
| Montageart | DIN rail mounting |
| Leerlaufprüfung | yes |
| Identifikation | UL/C-UL Listed UL 61010-1 |
| Einschaltstrom | < 21 A (25 °C) |
| Geräuschemission | EN 55016 |
| Störfestigkeit | Immunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial) |
| Produktfamilie | TRIO POWER |
| Zusätzlicher Text | Class 3 |
| EN 61010-2-201 | III (≤ 2000 m) |
| Frequenzbereich | 0 kHz ... 2 kHz |
| Restwelligkeit | typ. 50 mVPP(with nominal values) |
| Zustand | UOut> 21 V DC and IOutN (Contact closed) |
| Artikelüberarbeitung | 01 |
| Entladung in der Luft | 8 kV (Test Level 3) |
| Maximale Höhe | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Anzahl der Phasen | 1.00 |
| Positionsmarkierung | 3.1 (13), 3.2 (14) |
| Schutzklasse | I |
| Abstreiflänge | 10 mm (Rigid/flexible/ferrule) |
| Verbindungsmethode | Push-in connection |
| Kontaktentladung | 6 kV (Test Level 3) |
| Kontrollabweichung | < 1 % (change in load, static 10 % ... 90 %) |
| Geräte-Netzsicherung | 10 A internal (device protection) |
| Montageposition | horizontal DIN rail NS 35, EN 60715 |
| Anzahl der Perioden | 25 periods |
| Ausgangsleistung (PN) | 480 W |
| Schock (Operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Schaltspannung | max. 30 V DC (SELV) |
| Schutzschaltung | Transient protection; Varistor |
| Arten der Signalgebung | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Aktueller Verbrauch | 5.3 A (100 V AC) |
| Verschmutzungsgrad | 2 |
| Eingangsspannungsbereich | 100 V AC ... 240 V AC -15 % ... +10 % |
| Kurzschlussfest | yes |
| Testfeldstärke | 10 V/m (Test Level 3) |
| Reihenschaltung | yes, for increased output voltage (observe SELV limit) |
| Schutzgrad | IP20 |
| Frequenzbereich (fN) | 50 Hz ... 60 Hz ±10 % |
| LED an (rot), Kurzschluss | UOutOut > 0.9 x IN(On (red), ISHORT) |
| Netzpufferungszeit | typ. 23 ms (120 V AC) |
| Seitenelementversion | Aluminum |
| Standardbezeichnung | Safety of power supply units up to 1100 V (insulation distances) |
| Interferente Emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| LED leuchtet (grün), Gleichstrom OK | UOut> 21 V DC and IOutN (On (green), DC OK) |
| Niederspannungsrichtlinie | Conformance with Low Voltage Directive 2014/35/EC |
| Normen/Vorschriften | EN 61000-3-2 |
| Vibration (Betrieb) | 10 Hz ... 50 Hz, amplitude ±0.2 mm (IEC 60068-2-6) |
| Parallelschaltung | yes, for increased efficiency and redundancy |
| Nennausgangsspannung | 24 V DC |
| Leistungsfaktor (cos phi) | 0.96 (230 V AC) |
| Entladestrom zu PE | < 3.5 mA |
| Leitungsgebundene Störaussendung | EN 55016 |
| Normen/Spezifikationen | DIN EN 61558-2-16 |
| Strombelastbarkeit | max. 100 mA |
| LED an (rot blinkend) Überspannung | UOUT> OVP (Over voltage protection) (On (flashing red)) |
| Schaltkontakt (schwebend) | OptoMOS |
| Dynamischer Boost (IDyn.Boost) | max. 30 A (5 s) |
| Integrierter Sicherungsschutz | no |
| MTBF (IEC 61709, SN 29500) | > 1400000 h (25 °C) |
| Ausgangsleistung (PDyn. Boost) | max. 720 W (5 s) |
| Rückkopplungsspannungswiderstand | ≤ 35 V DC |
| LED an (gelb), IOut > 90 % | UOut> 21 V DC and IOut> 0.9 x IN(On (yellow), IOut> 90% ) |
| Nenneingangsspannungsbereich | 100 V AC ... 240 V AC |
| Nennausgangsstrom (IN) | 20 A |
| Konfiguration des Versorgungssystems | Star network (TN, TT, IT (PE)) |
| Leistungsverlust bei Nennlast (maximal). | < 26.72 W (230 V AC) |
| Elektromagnetische Verträglichkeit | Conformance with EMC Directive 2014/30/EU |
| Integral des Einschaltstroms (I2t) | < 1.091 A2s |
| Typische Spannung im nationalen Stromnetz | 120 V AC |
| Spannungsart der Versorgungsspannung | AC |
| Umgebungstemperatur (Betrieb) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Isolationsspannungseingang/-ausgang | 5.3 kV DC (type test) |
| Einbauabstand rechts/links | 0 mm / 0 mm |
| Einbauabstand oben/unten | 50 mm / 50 mm |
| Maximale Leerlaufverlustleistung | < 1.37 W (230 V AC) |
| Minimale Leerlaufverlustleistung | < 1.3 W (120 V AC) |
| Umweltschutzrichtlinie | RoHS Directive 2011/65/EU |
| Brennbarkeitsklasse gemäß UL 94 | V0 (Housing, terminal blocks) |
| Minimale Nennlastverlustleistung | < 33.37 W (120 V AC) |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 85 °C |
| Empfohlener Schutzschalter für den Eingang | 6 A ... 16 A (Characteristic B, C, D, K or comparable) |
| flexibel mit Hülse und Kunststoffhülse | 0.25 mm² ... 2.5 mm² |
| Umgebungstemperatur (getesteter Anlauftyp) | -40 °C |
| Einstellbereich der Ausgangsspannung (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| flexibel mit Hülse ohne Kunststoffhülse | 0.25 mm² ... 2.5 mm² |
| Maximal zulässige relative Luftfeuchtigkeit (Betrieb) | ≤ 95 % (at 25 °C, non-condensing) |
| Schutz gegen Überspannung am Ausgang (OVP) | ≤ 35 V DC |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung