| Parameter | Wert |
|---|---|
| 1817 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) | |
| MTTF | 6706 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| Notiz | Please follow the special installation instructions in the documentation! |
| Breite | 16 mm |
| Höhe | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
| Länge | 60 mm |
| Signal | RS-485 |
| Bussystem | Universal type for all systems |
| CCCex-Notiz | Use in potentially explosive areas is not permitted in China. |
| Zertifikat | PxCIF15ATEX2744241X |
| Produktart | Data plug |
| Identifikation | II 3 G Ex ec IIC T4 Gc |
| Pinbelegung | All connections are 1:1 on the screw terminal block |
| Artikelüberarbeitung | 09 |
| Abstreiflänge | 5 mm |
| Verbindungsmethode | D-SUB socket |
| Material (Gehäuse) | ABS (metal-plated) |
| Nennstrom IN | 100 mA |
| Nennspannung UN | 50 V DC |
| Maßzeichnung | |
| Übertragungsmedium | Copper |
| Schutzgrad | IP20 |
| Außendurchmesser des Kabels | 6 mm ... 10 mm (Incoming bus line) |
| Einführ-/Entfernungszyklen | > 200 |
| Umgebungstemperatur (Betrieb) | -20 °C ... 75 °C |
| Zulässige Luftfeuchtigkeit (Betrieb) | 10 % ... 95 % (non-condensing) |
| Leiterquerschnitt, starr max. | 1.5 mm² |
| Leiterquerschnitt, starr min. | 0.14 mm² |
| Leiterquerschnitt flexibel max. | 1 mm² |
| Leiterquerschnitt flexibel min. | 0.14 mm² |
| Umgebungstemperatur (Lagerung/Transport) | -25 °C ... 80 °C |
| Zulässige Luftfeuchtigkeit (Lagerung/Transport) | 5 % ... 95 % (non-condensing) |
| Maximaler AWG-Leiterquerschnitt, flexibel | 18 |
| Mindestquerschnitt des Leiters (AWG), flexibel | 26 |
| Einzeldraht-/Anschlusspunkt, starrer AWG max. | 16 |
| Einzeldraht/Anschlussstelle, starrer AWG min. | 26 |
| Frei von Substanzen, die das Aufbringen der Beschichtung beeinträchtigen könnten. | VDMA 24364:2018-05 |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung