

| Parameter | Wert |
|---|---|
| 95 V AC ... 120 V AC 10 % (96 W) | |
| Farbe | green |
| Tiefe | 61 mm |
| Eingang | asymmetrical 4 kV (Test Level 4) |
| Breite | 72 mm |
| starr | 0.2 mm² ... 2.5 mm² |
| Höhe | 90 mm |
| Ausgabe | asymmetrical 2 kV (Test Level 3) |
| LED aus | Supply voltage input AC not present (Off) |
| Stromspannung | 10 V (Test Level 3) |
| Kommentare | Criterion A |
| Leistungsreduzierung | > 50 °C ... 70 °C (2 % / K) |
| Funktion | Visual operating state display |
| Position | 1.x |
| flexibel | 0.2 mm² ... 2.5 mm² |
| Frequenz | 50 Hz |
| Aufstiegszeit | typ. 100 ms (UOut= 10 % ... 90 %) |
| EN 61010-1 | II (≤ 5000 m) |
| EN 62477-1 | III (≤ 2000 m) |
| Effizienz | > 94 % (120 V AC) |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Kriterium C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Spannungseinbruch | 70 % |
| starr (AWG) | 24 ... 14 (Cu) |
| Crest-Faktor | typ. 1,64 (120 V AC) |
| Produktart | Power supply |
| Montageart | DIN rail or direct mounting |
| Leerlaufprüfung | yes |
| Identifikation | UL/C-UL Listed UL 61010-1 |
| Einschaltstrom | typ. 35 A |
| Geräuschemission | EN 55016 |
| Störfestigkeit | EN 61000-6-2:2005 |
| Produktfamilie | STEP POWER |
| Einschaltzeit | typ. 2 s |
| Zusätzlicher Text | Class 3 |
| Frequenzbereich | 0 kHz ... 2 kHz |
| Restwelligkeit | typ. 100 mVPP |
| Entladung in der Luft | 8 kV (Test Level 3) |
| Horizontale Neigung | 4 Div. (DIN 43880) |
| Gehäusematerial | Plastic |
| Maximale Höhe | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Anzahl der Phasen | 1.00 |
| Positionsmarkierung | 1.1, 1.2 (L), 1.3, 1.4 (N) |
| Schutzklasse | II (in closed control cabinet) |
| Abstreiflänge | 10 mm (rigid/flexible/ferrule without plastic sleeve) |
| Verbindungsmethode | Push-in connection |
| Kontaktentladung | 6 kV (Test Level 3) |
| Kontrollabweichung | < 0.5 % (Static load change 10 % ... 90 %) |
| Geräte-Netzsicherung | 4 A internal (device protection), slow-blow |
| Montageposition | horizontal DIN rail NS 35, EN 60715 |
| Anzahl der Perioden | 25 periods |
| Ausgangsleistung (PN) | 120 W |
| Schock (Operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Schutzschaltung | Transient surge protection; Varistor |
| Arten der Signalgebung | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Aktueller Verbrauch | 1.11 A (120 V AC) |
| Verschmutzungsgrad | 2 |
| Maßzeichnung | |
| Material für Fußriegel | Polyamid |
| Eingangsspannungsbereich | 120 V AC ... 240 V AC 10 % (120 W) |
| Kurzschlussfest | yes |
| Testfeldstärke | 10 V/m (Test Level 3) |
| Reihenschaltung | yes, for increased output voltage |
| Schutzgrad | IP20 |
| Frequenzbereich (fN) | 50 Hz ... 60 Hz ±10 % |
| Netzpufferungszeit | typ. 19 ms (120 V AC) |
| Standardbezeichnung | Electrical safety |
| Montageanleitung | alignable: 0 mm horizontally, 30 mm vertically |
| Interferente Emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| LED leuchtet (grün), Gleichstrom OK | UOut>44 V DC (on) |
| Niederspannungsrichtlinie | Conformance with Low Voltage Directive 2014/35/EC |
| Normen/Vorschriften | EN 61000-3-2 |
| Vibration (Betrieb) | < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6) |
| Parallelschaltung | yes, for increasing power and redundancy with diode |
| Nennausgangsspannung | 48 V DC |
| Entladestrom zu PE | < 0.25 mA |
| Mit Schutzbeschichtung | No |
| Leitungsgebundene Störaussendung | EN 55016 |
| Normen/Spezifikationen | IEC 61010-1 (SELV) |
| MTBF (IEC 61709, SN 29500) | > 1372000 h (25 °C) |
| Rückkopplungsspannungswiderstand | ≤ 60 V DC |
| Nennausgangsstrom (IN) | 2.5 A (120 W) |
| Konfiguration des Versorgungssystems | Star network (TN, TT, IT (PE)) |
| Leistungsverlust bei Nennlast (maximal). | < 5.7 W (230 V AC) |
| Elektromagnetische Verträglichkeit | Conformance with EMC Directive 2014/30/EU |
| Integral des Einschaltstroms (I2t) | typ. 0.03 A2s |
| Typische Spannung im nationalen Stromnetz | 120 V AC |
| Spannungsart der Versorgungsspannung | AC |
| Umgebungstemperatur (Betrieb) | -10 °C ... 70 °C (Derating: > 50 °C; 2 %/K) |
| Einbauabstand rechts/links | 0 mm / 0 mm |
| Einbauabstand oben/unten | 30 mm / 30 mm |
| Maximale Leerlaufverlustleistung | < 0.21 W (230 V AC) |
| Minimale Leerlaufverlustleistung | < 0.21 W (120 V AC) |
| Umweltschutzrichtlinie | RoHS Directive 2011/65/EU |
| Minimale Nennlastverlustleistung | < 7.7 W (120 V AC) |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 85 °C |
| Empfohlener Schutzschalter für den Eingang | 6 A ... 16 A (Characteristics B, C, D, K) |
| flexibel mit Hülse und Kunststoffhülse | 0.2 mm² ... 1 mm² |
| Umgebungstemperatur (getesteter Anlauftyp) | -25 °C |
| Einstellbereich der Ausgangsspannung (USet) | 48 V DC ... 56 V DC (> 48 V DC, constant capacity restricted) |
| flexibel mit Hülse ohne Kunststoffhülse | 0.5 mm² ... 1.5 mm² |
| Maximal zulässige relative Luftfeuchtigkeit (Betrieb) | ≤ 95 % (at 25 °C, non-condensing) |
| Schutz gegen Überspannung am Ausgang (OVP) | < 60 V DC |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung