| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| PFHD | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| Gewicht | Net weight: 250 g approx. |
| Details | Applicantion expansion unit for the SF4B series |
| Produkt | Exclusive Control Unit for Safety Light Curtain |
| Material | Enclosure: ABS |
| Teilenummer | SF-C14EX |
| Produktname | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Netzspannung | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Produktnummer | SF-C14EX |
| Umgebungsfeuchtigkeit | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Kontrollkategorie | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Stoßfestigkeit | 30 G acceleration in X, Y and Z directions three times each |
| Lampenausgang stummschalten | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Umgebungstemperatur | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| Anschlussklemme | Detachable spring-cage terminal |
| Aktueller Verbrauch | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Vibrationsfestigkeit | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Anwendbare Normen: Japan | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Einhaltung der CE-Kennzeichnungsrichtlinie | Machinery Directive, EMC Directive, RoHS Directive |
| Anwendbare Normen: Europa (EU) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Verbindbare Sicherheitslichtvorhänge | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| Anwendbare Normen: Nordamerika | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Lampenausgang stummschalten: Schutzschaltung | Incorporated |
| Anwendbare Normen: Internationaler Standard | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| Umweltbeständigkeit: Schutzgrad | Enclosure: IP40Terminal: IP20 |
| Umweltbeständigkeit: Durchschlagsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): Reaktionszeit | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): Betriebsart (Ausgangsbetrieb) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): Schutzschaltung (Kurzschlussschutz) | Incorporated |
| Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4): Betriebsmodus (Ausgangsbetrieb) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4): Schutzschaltung (Kurzschlussschutz) | Incorporated |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung