Wichtige Spezifikationen
Artikel:Specifications
PFHD:1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD:100 years or more(Note:Mean time to dangerous failure (in years))
Gewicht:Net weight: 250 g approx.
Lieferanteninformation
PANASONIC
PANASONIC
Produkte: 4316
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
ArtikelSpecifications
PFHD1.66 × 10-10(Note:Probability of dangerous failure per hour)
MTTFD100 years or more(Note:Mean time to dangerous failure (in years))
GewichtNet weight: 250 g approx.
DetailsApplicantion expansion unit for the SF4B series
ProduktExclusive Control Unit for Safety Light Curtain
MaterialEnclosure: ABS
TeilenummerSF-C14EX
ProduktnameExclusive Control Unit for Safety Light Curtain SF-C10
Netzspannung24 V DC plus or minus 10 % Ripple P-P 10 % or less
ProduktnummerSF-C14EX
Umgebungsfeuchtigkeit30 to 85 % RH, Storage: 30 to 95 % RH
KontrollkategorieISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Stoßfestigkeit30 G acceleration in X, Y and Z directions three times each
Lampenausgang stummschaltenApplicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Umgebungstemperatur-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉
AnschlussklemmeDetachable spring-cage terminal
Aktueller Verbrauch0.2 A or less (Excluding Safety light curtain and other external connecting device)
Vibrationsfestigkeit10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each
Isolationswiderstand20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure
Anwendbare Normen: JapanJIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe)
Einhaltung der CE-KennzeichnungsrichtlinieMachinery Directive, EMC Directive, RoHS Directive
Anwendbare Normen: Europa (EU)EN 55011, EN ISO 13849-1 (Category 4, PLe)
Verbindbare SicherheitslichtvorhängeSF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.)
Anwendbare Normen: NordamerikaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Lampenausgang stummschalten: SchutzschaltungIncorporated
Anwendbare Normen: Internationaler StandardIEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe)
Umweltbeständigkeit: SchutzgradEnclosure: IP40Terminal: IP20
Umweltbeständigkeit: Durchschlagsfestigkeit1,000 V AC for one min. between all supply terminals connected together and enclosure
Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3)PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current)
Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): ReaktionszeitOFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3.
Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4)PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current)
Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): Betriebsart (Ausgangsbetrieb)Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid
Sicherheitsausgänge (Sicherheitsausgang 1, Sicherheitsausgang 2, Sicherheitsausgang 3): Schutzschaltung (Kurzschlussschutz)Incorporated
Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4): Betriebsmodus (Ausgangsbetrieb)Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.)
Hilfsausgänge (Hilfsausgang 1, Hilfsausgang 2, Hilfsausgang 3, Hilfsausgang 4): Schutzschaltung (Kurzschlussschutz)Incorporated

Produktbeschreibung

SF-C14EX_Exclusive Control Unit for Safety Light Curtain_Exclusive Control Unit for Safety Light Curtain SF-C10_Applicantion expansion unit for the SF4B series
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top