| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| PFHD | 6.2 × 10-9(Note) Probability of dangerous failure per hour. |
| Kabel | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| Details | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
| Produkt | Compact Safety Light Curtain[Type4 PLe SIL3] |
| Material | Enclosure: Polycarbonate |
| Balkenneigung | 20 mm0.787 in |
| Zubehör | SF4B-TR25 (Test rod): 1 pc. |
| Teilenummer | SF4B-H88CA-J05 |
| Produktname | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
| ELCA-Funktion | Incorporated (reducing mutual interference automatically) |
| Netzspannung | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Ansprechzeit | OFF response: 14 ms or lessON response: 80 to 90 ms |
| Produktnummer | SF4B-H88CA-J05 |
| Kabelverlängerung | Extension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables |
| Stummschaltungsfunktion | Incorporated |
| Betriebsbereich | 0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| Umgebungsfeuchtigkeit | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Emitterelement | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
| Verschmutzungsgrad | 3 |
| Stoßfestigkeit | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
| Überschreiben-Funktion | Incorporated |
| Schutzhöhe | 1,783.4 mm 70.212 in |
| Verriegelungsfunktion | Incorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| Betriebshöhe | 2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| Optionale Funktionen | Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required. |
| Umgebungsbeleuchtungsstärke | Incandescent light: 3,500 liter x or less at the light-receiving face |
| Umgebungstemperatur | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
| Mindestens Erfassungsobjekt | ø25 mm ø0.984 in opaque object(Note) In case the blanking function is valid, the operation mode is changed. |
| Anzahl der Strahlkanäle | 88 |
| Vibrationsfestigkeit | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
| Isolationswiderstand | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Emissionsstoppfunktion | Incorporated |
| Hilfsausgang stummschalten | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable) |
| Effektiver Öffnungswinkel | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| Anwendbare Normen: Japan | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) |
| Einhaltung der CE-Kennzeichnungsrichtlinie | Machine Directive, EMC Directive, RoHS Directive |
| Anwendbare Normen: Europa (EU) | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| Steuerausgänge (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less |
| Anwendbare Normen: Nordamerika | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognizedsafety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7 |
| Funktion zur Überwachung externer Geräte | Incorporated |
| Hilfsausgang (Nicht-Sicherheitsausgang) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
| Große Mehrzweck-Anzeigefunktion | Incorporated |
| Stummschaltung des Hilfsausgangs: Betriebsmodus | When muting auxiliary output: ON |
| Anwendbare Standards: Südkorea (S-Zeichen) | S1-G-35-2005, S2-W-11-2003 |
| Stummschaltung des Hilfsausgangs: Schutzschaltung | Incorporated |
| Nettogewicht (Gesamtgewicht von Sender und Empfänger) | approx. 1,800 g |
| Anwendbare Normen: Internationaler Standard | IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) |
| Umweltbeständigkeit: Schutzgrad | IP65 (IEC) |
| Steuerausgänge (OSSD 1, OSSD 2): Betriebsmodus | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change. |
| Steuerausgänge (OSSD1, OSSD2): Schutzschaltung | Incorporated |
| Hilfsausgang (Nicht-Sicherheitsausgang): Betriebsmodus | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
| Umweltbeständigkeit: Durchschlagsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Hilfsausgang (Nicht-Sicherheitsausgang): Schutzschaltung | Incorporated |
| Aktueller Verbrauch: Große Mehrzweckanzeige leuchtet auf | Emitter: 110 mA or lessReceiver: 155 mA or less |
| Aktueller Verbrauch: Große Mehrzweck-Anzeigeleuchten aus | Emitter: 100 mA or lessReceiver: 140 mA or less |