| Parameter | Wert |
|---|---|
| • WARNING: Serve only products in perfect condition. Products should be checked regularly for damage. Remove defective products immediately. Replace damaged products. It is not possible to repair them. | |
| Abgeschirmt | No |
| Kabeltyp | TPE braided yarn |
| Steckerzyklen | > 100 |
| Sensortyp | Universal |
| Kabellänge | 0.5 m |
| Kodifizierung | to |
| Linienabschnitt | 0.34 mm² |
| Produkttyp | Circular connectors (equipment side) |
| Sicherheitshinweise | WARNING: Connectors should not be plugged in or unplugged under load. Failure to comply and improper use can result in property damage and personal injury. |
| Stoßwellenkategorie | Ii |
| AWG-Signalleitung | 22 |
| Verbindungstyp | Single braided threads |
| Dichtungsmaterial | FKM |
| Leitungswiderstand | ≤ 57.6 mΩ/m |
| Anzahl der Pole | 5 |
| Kontaktmaterial | CuZn |
| Schutzindex | IP67 (In plugged in state) |
| Regeln/Bestimmungen | IEC 61076-2-101 |
| Montageart | Rear wall mount |
| Anzugsmoment | 3 Nm ... 4 Nm (on the mounting side) |
| Kontaktwiderstand | ≤ 3 mΩ |
| Header-Gewindetyp | M12 |
| Nennstrom IN | 4 A |
| Nennspannung UN | 60 V |
| Prüfspannungskabel | 2000 V AC |
| Leitfähiges Material | Tinned Cu Conductor |
| Verschmutzungsgrad | 3 |
| Kopfkonstruktion | Male connector |
| Signalart/Kategorie | Universal |
| Einzeltreiber, Farbe | black, brown, blue, white, gray |
| Isolationswiderstand | ≥ 100 MΩ |
| Nennspannungskabel | 300 V |
| Anzahl der Kabelanschlüsse | 1 |
| Kontakt-Supportmaterial | AP 6.6 |
| Bezeichnung des Standards | M12 connector |
| Installationsanleitung | with flat nut |
| Material: Kontaktfläche | Au |
| Maximaler Leiterwiderstand | 57.6 mΩ/m |
| Schraubverbindungsmaterial | Zinc die-cast iron, nickel-plated |
| Wandstärkenisolierung | 0.21 mm (Conductor Insulation) |
| Leitungsisolationswiderstand | ≥ 20 MΩ*km |
| Umgebungstemperatur (Betrieb) | -40 °C ... 85°C (cable, fixed arrangement) |
| Dimensionierung von transienten Spannungen | 1.5 kV |
| Material: Leiterisolierung | TPE |
| Leiterkonstruktion Signalkabel | 7x 0.25 mm |
| Leiterdurchmesser inkl. Isolierung | 1.2 mm ±0.07 mm |
| Anmerkung zum Betrieb | The electrical and mechanical values listed require a pair of plug-in connectors that are properly assembled and locked. If the plug-in connector is unlocked and there is a danger of contamination, the plug-in connector must be closed with a cap > IP54. In addition, influences by conductors, lines, or assembly of printed circuit boards must be considered. |
| Entflammbarkeitsklasse gemäß UL 94 | V0 |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung