RPT-160A - RPT-160A MEANWELL AC-DC Triple output Medical Open frame power supply, Output 5VDC / 14A +12VDC / 5.5A -5VDC..
Vorrätig Top‑Produkt

RPT-160A

RPT-160A MEANWELL AC-DC Triple output Medical Open frame power supply, Output 5VDC / 14A +12VDC / 5.5A -5VDC..

$64.50USD
200 auf Lager
Wichtige Spezifikationen
Name:RPT-160A
Zustand:New
Alarm:Powerfail, Output OK
Format:Open Format
Lieferanteninformation
MEANWELL
MEANWELL
Produkte: 6448
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Technische Spezifikationen

ParameterWert
NameRPT-160A
ZustandNew
AlarmPowerfail, Output OK
FormatOpen Format
SerieRPT-160
Ausgang 1+5
Ausgang 2+12
Ausgang 3-5
GenehmigungenEC, EAC, EN60601 3rd Edition, UL
Leistung (W)98,60
Subformato5"x3"
Breite (mm)76.2
Höhe (mm)34.6
AC-Eingangsleistung Max.264,00
Mindesteingangsleistung (AC): Mindestens90,00
AnwendungenIndustrial, Medical, Telecommunications
HerstellerMEAN WELL
ProduktartPower supply AC/DC
Isolation (V)4.000,00
Spitzenleistung (W)One hundred forty five
EingangsanschlussPlug-in
Eingangsfrequenz50 Hz, 60 Hz
Lang/HintergrundOne hundred twenty seven
Lange BeschreibungMedical power supply in open format(Open-Frame).Range of universal input90-264vac47-63Hz.Outputs:-5vdc:Minimum intensity of output0.1 To.Maximum output current0,6Amp.+5vdc:Minimum intensity of output0.6 To.Maximum output currentNineAmps.+12vdc:Minimum intensity of output0.2 To.Maximum output current3,8Amps.Power:98,6 WandOne hundred forty fiveW with external fan.Source certified for medical applications2 xMOPP(the patient protection).Leakage current < 160µA.Factor corrector, power>0.93to 230vac at full load.Efficiency:84%.Working temperature: from-20up+70ºCof ambient temperature. Consult the technical data sheet to see the curves of drift.Dimensions (Length x Width x Height) [mm]:127 x 76.2 x 34,6.3 years of warranty.Manufacturer: MEAN WELL.The series RPT-160 power supply certified for medical use with patient protection, 2 x MOPP (means of patient protection). They have a double protection between input and output 2xMOPP and protection between input and ground 1xMOPP.Have a leakage current (contact current) is very low for a greater security in the application. Can operate with cooling by free air circulation or provide a higher power through the use of an external fan.
AusgangsanschlussPlug-in
Art des Eintrags CASingle-phase
Garantie (Jahre)3,00
UrsprungslandChina
Sie müssen mindestens ladenYes

Produktbeschreibung

More details
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Technische Details

Medical power supply in open format(Open-Frame).

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top