| Parameter | Wert |
|---|---|
| • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. | |
| Farbe | black |
| Breite | 18.6 mm |
| Höhe | 18.6 mm |
| Länge | 43.15 mm |
| Kabeltyp | Multi-standard |
| Sicherheitshinweis | • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. |
| Kabellänge | 1500 mm |
| Produktart | Panel feed-through |
| Dichtungsmaterial | EPDM |
| Produktfamilie | SUNCLIX |
| O-Ring-Material | Silopren |
| Kontaktmaterial | Cu |
| Gehäusematerial | PPE |
| Schutzklasse | II |
| Kontaktwiderstand | 0.45 mΩ |
| Kabeldichtungsmaterial | Elastosil |
| Verschmutzungsgrad | 2 |
| Maßzeichnung | |
| Nennspannung (II/2) | 1000 V |
| Nennspannung (III/2) | 1500 V |
| Äußere Hülle, Farbe | black |
| Kontaktträgermaterial | PPE |
| Kontaktflächenmaterial | Ag |
| Bemessungsstrom (6,0 mm²) | 35 A |
| Farbe des Gehäuseteils | black |
| Isoliermaterialgruppe | I / CTI 600 |
| Bemessungsstoßspannung (II/2) | 8 kV |
| Bemessungsstoßspannung (III/2) | 8 kV |
| Bemessungsstoßspannung (III/3) | 16 kV |
| Schutzart (nicht angeschlossen) | IP20 |
| Schutzgrad (im eingesteckten Zustand) | IP66 / IP68 (2 m / 24 h) |
| Brennbarkeitsklasse gemäß UL 94 | V0 |
| Aufbau einzelner Litzen nach VDE 0295 / kleinster Drahtdurchmesser | VDE 0295 class 5 |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung