| Parameter | Wert |
|---|---|
| 250 V AC | |
| Tiefe | 114.5 mm |
| Schock | 15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.) |
| Breite | 17.5 mm |
| Höhe | 112.2 mm |
| Aktuell | max. 100 mA |
| Stromspannung | typ. 23 V DC (US- 1 V) |
| Kategorie | 4 (In conjunction with suitable evaluating device) |
| steckbar | yes |
| Relais-Typ | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Anwendung | Extension module |
| Bezeichnung | A1/A2 |
| Filterzeit | 4 ms (at A1 in the event of voltage dips at Us) |
| Ausgangssicherung | 10 A gL/gG |
| Produktart | Safety relays |
| Schraubengewinde | M3 |
| Montagehinweis | See derating curve |
| Montageart | DIN rail mounting |
| Erholungszeit | < 100 ms |
| Stoppkategorie | 0 |
| Identifikation | CE-compliant |
| Einschaltstrom | typ. 125 mA (Δt = 7 ms at Us) |
| Produktfamilie | PSRmini |
| Statusanzeige | 2 x LED (green) |
| Farbe (Gehäuse) | yellow (RAL 1018) |
| Artikelüberarbeitung | 06 |
| Kontaktmaterial | AgSnO2 |
| Gehäusematerial | Polyamide |
| Maximale Höhe | max. 2000 m (Above sea level) |
| Abstreiflänge | 7 mm |
| Verbindungsmethode | Screw connection |
| Montageposition | vertical or horizontal |
| Anzahl der Ausgänge | 5 (undelayed) |
| Quadratischer Gesamtstrom | 64 A2(observe derating) |
| Schaltspannung | min. 5 V AC/DC |
| Ausgabebeschreibung | safety-related N/O contacts |
| Schutzschaltung | Surge protection; Suppressor diode |
| Schaltkapazität | min. 50 mW (5 V / 10 mA) |
| Hinweis zur Anwendung | Only for industrial use |
| Schaltfrequenz | max. 0.5 Hz |
| Schutzgrad | IP20 |
| Typische Veröffentlichungszeit | < 25 ms (when controlled via A1/A2) |
| Normen/Vorschriften | EN 60947-1 |
| Typische Reaktionszeit | < 50 ms (Monitored/manual and auto-start) |
| Vibration (Betrieb) | 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
| Kontaktschaltart | 5 enabling current paths |
| Maximaler Einschaltstrom | 500 mA (Δt = 1 ms at Us) |
| Nominaler Betriebsmodus | 100% operating factor |
| Leistungsniveau (PL) | e (In conjunction with suitable evaluating device) |
| Mechanische Lebensdauer | 10x 106cycles |
| Stromverbrauch in den USA | typ. 1.92 W |
| Bemessungsisolationsspannung | 250 V AC |
| Kurzschlussschutz | Yes |
| Typische Startzeit bei uns | < 50 ms (when controlled via A1/A2) |
| Leiterquerschnitt AWG | 24 ... 12 |
| Begrenzung des Dauerstroms | 6 A (observe derating) |
| Sicherheitsintegritätsniveau (SIL) | 3 (In conjunction with suitable evaluating device) |
| Leiterquerschnitt starr | 0.2 mm² ... 2.5 mm² |
| Bemessungsstoßspannung/Isolierung | |
| Umgebungstemperatur (Betrieb) | -20 °C ... 60 °C (observe derating) |
| Bemessungssteuerstrom IS | typ. 80 mA |
| Leiterquerschnitt flexibel | 0.2 mm² ... 2.5 mm² |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 80 °C |
| Bemessungsversorgungsspannung des Steuerkreises (US) | 19.2 V DC ... 30 V DC |
| Mindestschutzgrad des Anlagenstandorts | IP54 |
| Maximal zulässige Luftfeuchtigkeit (Lagerung/Transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximal zulässige relative Luftfeuchtigkeit (Betrieb) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximale Verlustleistung im Nennbetrieb | 15.2 W (at US= 30 V, IL² = 64 A²) |
| Schaltleistung gemäß IEC 60947-5-1 | 3 A (24 V (DC13)) |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung