| Parameter | Wert |
|---|---|
| 230 V AC | |
| Zeit | 50000 h |
| Farbe | green |
| Tiefe | 100 mm |
| Eingang | 4 kV (Test Level 4 - asymmetrical) |
| Breite | 33 mm |
| starr | 0.5 mm² ... 2.5 mm² |
| Höhe | 90 mm |
| Ausgabe | 2 kV (Test Level 3 - asymmetrical) |
| Aktuell | 2.5 A |
| LED aus | Supply voltage input AC not present (Off) |
| Stromspannung | 10 V (Test Level 3) |
| Kommentare | Criterion A |
| Funktion | Visual operating state display |
| Position | 1.x |
| flexibel | 0.5 mm² ... 2.5 mm² |
| Frequenz | 50 Hz |
| Aufstiegszeit | < 100 ms (UOut= 10 % ... 90 %) |
| EN 61010-1 | II (≤ 3000 m) |
| Effizienz | typ. 88 % (120 V AC) |
| Kriterium A | Normal operating behavior within the specified limits. |
| Kriterium B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Kriterium C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Temperatur | 40 °C |
| Spannungseinbruch | 70 % |
| starr (AWG) | 20 ... 14 (Cu) |
| Crest-Faktor | typ. 3 (120 V AC) |
| Hood-Version | Stainless steel |
| Eingang/Ausgang | asymmetrical |
| Produktart | Power supply |
| Montageart | DIN rail mounting |
| Leerlaufprüfung | yes |
| Klimaklasse | 3K22 (in accordance with EN 60721-3-3) |
| Identifikation | 1.1 (), 1.2 (L), 1.3 (N) |
| Einschaltstrom | typ. 27 A (at 25 °C) |
| Geräuschemission | EN 55016 |
| Produktfamilie | ESSENTIAL POWER |
| Einschaltzeit | typ. 1 s |
| Zusätzlicher Text | 120 V AC |
| Frequenzbereich | 0 kHz ... 2 kHz |
| Restwelligkeit | typ. 30 mVPP(with nominal values) |
| Entladung in der Luft | 8 kV (Test Level 3) |
| Gehäusematerial | Plastic |
| Maximale Höhe | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Anzahl der Phasen | 1.00 |
| Schutzklasse | II |
| Abstreiflänge | 6.5 mm |
| Verbindungsmethode | Screw connection |
| Kontaktentladung | 6 kV (Test Level 3) |
| Kontrollabweichung | < 2 % (change in load, static 10 % ... 90 %) |
| Geräte-Netzsicherung | 3.15 A internal (device protection), fast-blow |
| Montageposition | horizontal DIN rail NS 35, EN 60715 |
| Anzahl der Perioden | 25 periods |
| Ausgangsleistung (PN) | 60 W (240 V AC) |
| Schock (Operation) | 15 ms, 15 g, per spatial direction (IEC 60068-2-27) |
| Anzugsmoment | 0.5 Nm ... 0.6 Nm |
| Schutzschaltung | Transient protection; Varistor |
| Arten der Signalgebung | LED DC OK – signal state operation (UN= 24 V DC, IOut= IN) |
| Aktueller Verbrauch | max. 1.5 A |
| Verschmutzungsgrad | 2 |
| Material für Fußriegel | Polyamid |
| Eingangsspannungsbereich | 100 V AC ... 240 V AC -15 % ... +10 % (PN= 60 W) |
| Kurzschlussfest | yes |
| Testfeldstärke | 10 V/m (Test Level 3) |
| Reihenschaltung | yes, for increased output voltage |
| Schutzgrad | IP20 |
| Frequenzbereich (fN) | 50 Hz ... 60 Hz ±10 % |
| Netzpufferungszeit | typ. 14 ms (120 V AC) |
| Seitenelementversion | Aluminum |
| Standardbezeichnung | Electrical safety |
| Montageanleitung | alignable: 0 mm horizontally, 30 mm vertically |
| Antriebsformschraubenkopf | Slotted L |
| Interferente Emission | Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial) |
| LED leuchtet (grün), Gleichstrom OK | UOUT> 17.5 V (On (green), DC OK) |
| Niederspannungsrichtlinie | Conformance with Low Voltage Directive 2014/35/EC |
| Normen/Vorschriften | EN 61000-3-2 |
| Vibration (Betrieb) | 10 Hz ... 50 Hz, amplitude ±0.2 mm |
| Parallelschaltung | yes, for increasing power and redundancy with diode |
| Nennausgangsspannung | 24 V DC |
| Entladestrom zu PE | < 3.5 mA |
| MTBF (Telcordia SR-332) | > 2800000 h (25 °C) |
| Mit Schutzbeschichtung | No |
| Leitungsgebundene Störaussendung | EN 55016 |
| Normen/Spezifikationen | IEC 61010-2-201 (SELV) |
| Integrierter Sicherungsschutz | no |
| Rückkopplungsspannungswiderstand | ≤ 35 V DC |
| Nenneingangsspannungsbereich | 100 V AC ... 240 V AC |
| Nennausgangsstrom (IN) | max. 2.5 A |
| Konfiguration des Versorgungssystems | TN, TT, IT (PE) |
| Leistungsverlust bei Nennlast (maximal). | < 7 W (230 V AC) |
| Elektromagnetische Verträglichkeit | Conformance with EMC Directive 2014/30/EU |
| Integral des Einschaltstroms (I2t) | typ. 0.5 A2s |
| Isolationsspannungseingang / PE | 3.5 kV AC (type test) |
| Typische Spannung im nationalen Stromnetz | 120 V AC |
| Spannungsart der Versorgungsspannung | AC |
| Umgebungstemperatur (Betrieb) | -20 °C ... 70 °C (Derating >45°C: 2.5%/K) |
| Isolationsspannungseingang/-ausgang | 4 kV AC (type test) |
| Einbauabstand rechts/links | 10 mm / 10 mm |
| Einbauabstand oben/unten | 30 mm / 30 mm |
| Maximale Leerlaufverlustleistung | < 1 W (230 V AC) |
| Minimale Leerlaufverlustleistung | < 1 W (120 V AC) |
| EMV-Anforderungen an die Störfestigkeit | EN 61000-6-2 |
| Minimale Nennlastverlustleistung | < 9 W (120 V AC) |
| Umgebungstemperatur (Lagerung/Transport) | -40 °C ... 85 °C |
| Empfohlener Schutzschalter für den Eingang | 6 A ... 16 A (Characteristic B, C, D, K or comparable) |
| flexibel mit Hülse und Kunststoffhülse | 0.5 mm² ... 2.5 mm² |
| Einstellbereich der Ausgangsspannung (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| flexibel mit Hülse ohne Kunststoffhülse | 0.5 mm² ... 2.5 mm² |
| Maximal zulässige relative Luftfeuchtigkeit (Betrieb) | ≤ 95 % (at 25 °C, non-condensing) |
| Schutz gegen Überspannung am Ausgang (OVP) | ≤ 35 V DC |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung