Servicezeiten: Montag bis Freitag 9:00-18:00
HSP-200-4.2 - HSP-200-4.2 MEANWELL AC-DC Single output enclosed power supply with PCF, Output 4.2VDC / 40A, 1U low profile..
Vorrätig Top‑Produkt

HSP-200-4.2

HSP-200-4.2 MEANWELL AC-DC Single output enclosed power supply with PCF, Output 4.2VDC / 40A, 1U low profile..

$0.00USD
4355 auf Lager
Lieferanteninformation
MEANWELL
MEANWELL
Produkte: 6448
Versand in der Regel innerhalb von 2-3 Werktagen
Qualität garantiert
Schneller Versand
Technischer Support

Produktbeschreibung

More details
Hauptmerkmale
  • Qualität in Industrieklasse
  • RoHS-konform
  • CE-zertifiziert
  • 1‑Jahresgarantie

Technische Details

200W Single Output with PFC Function 200W Single Output with PFC Function200W Single Output with PFC Function HSP-200series HSP-200seriesHSP-200series Features : Features :Features : UniversalAC input / Full range UniversalAC input / Full rangeUniversalAC input / Full range Built-in active PFC function Built-in active PFC functionBuilt-in active PFC function Low leakage current<1.0mA Low leakage current<1.0mALow leakage current<1.0mA Protections: Short circuit / Overload / Over voltage/ Over temperature Protections: Short circuit / Overload / Over voltage/ Over temperatureProtections: Short circuit / Overload / Over voltage/ Over temperature Low profile:31mm Low profile:31mmLow profile:31mm Conformalcoated ConformalcoatedConformalcoated LED indicator for power on LED indicator for power onLED indicator for power on 3 years warranty 3 years warranty3 years warrantySPECIFICATION SPECIFICATIONSPECIFICATION Bauar t gepr u f t Bauar t gepr u f tBauar t gepr u f t Sicherheit egel ma ge Sicherheit egel ma geSicherheit egel ma ge od o s od o sod o s be wacg be wacgbe wacg www. tuv. com www. tuv. comwww. tuv. com ID 2000000000 ID 2000000000ID 2000000000 MODEL MODELMODEL DC VOLTAGE RATED CURRENT CURRENT RANGE DC VOLTAGE RATED CURRENT CURRENT RANGEDC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER(convection) RATED POWER(convection)RATED POWER(convection) HSP-200-4.2 HSP-200-4.2HSP-200-4.2 4.2V 4.2V4.2V 40A 40A40A 0 ~ 40A 0 ~ 40A0 ~ 40A 168W 168W168W HSP-200-5 HSP-200-5HSP-200-5 5V 5V5V 40A 40A40A 0 ~ 40A 0 ~ 40A0 ~ 40A 200W 200W200W RIPPLE & NOISE (max.) Note.2150mVp-p RIPPLE & NOISE (max.) Note.2150mVp-pRIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p 150mVp-p150mVp-p OUTPUT OUTPUTOUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LINE REGULATIONLINE REGULATION LOAD REGULATION LOAD REGULATIONLOAD REGULATION 3.6~4.4V 3.6~4.4V3.6~4.4V 2.0% 2.0%2.0% 0.5% 0.5%0.5% 1.0% 1.0%1.0% 4.5~5.5V 4.5~5.5V4.5~5.5V 2.0% 2.0%2.0% 0.5% 0.5%0.5% 1.0% 1.0%1.0% SETUP, RISE TIME HOLD UP TIME (Typ.) SETUP, RISE TIME HOLD UP TIME (Typ.)SETUP, RISE TIME HOLD UP TIME (Typ.) 2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load 2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load 16ms/230VAC16ms/115VAC at full load 16ms/230VAC16ms/115VAC at full load16ms/230VAC16ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDCVOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC INPUT INPUTINPUT FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.)FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENTAC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT 47 ~ 63Hz 47 ~ 63Hz47 ~ 63Hz PF0.95/230VACPF 0.98/115VAC at full load PF0.95/230VACPF 0.98/115VAC at full loadPF0.95/230VACPF 0.98/115VAC at full load 88% 88%88% 2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC 2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC2.5A/115VAC 1.5A/230VAC Cold start 70A/230VAC <1.0mA / 240VAC <1.0mA / 240VAC<1.0mA / 240VAC 110~140% rated output power 110~140% rated output power110~140% rated output power88.5% 88.5%88.5% 3.0A/115VAC 2.0A/230VAC 3.0A/115VAC 2.0A/230VAC3.0A/115VAC 2.0A/230VAC OVERLOAD OVERLOADOVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removedProtection type : Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removedSHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION PROTECTIONPROTECTION 4.6 ~ 5.4V 4.6 ~ 5.4V4.6 ~ 5.4V 5.6 ~ 7.0V 5.6 ~ 7.0V5.6 ~ 7.0VENVIRONMENT ENVIRONMENTENVIRONMENT SAFETY & EMC SAFETY & EMCSAFETY & EMC (Note 5) (Note 5)(Note 5) OTHERS OTHERSOTHERS OVER VOLTAGE OVER VOLTAGEOVER VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITYOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY STORAGE TEMP., HUMIDITYSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION TEMP. COEFFICIENT VIBRATIONTEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY STANDARDSSAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSIONWITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSIONEMC IMMUNITY MTBF DIMENSION PACKING PACKINGPACKING Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removedProtection type : Hiccup mode, recovers automatically after fault condition is removed Shut down O/P voltage, recovers automatically after fault condition is removed Shut down O/P voltage, recovers automatically after fault condition is removedShut down O/P voltage, recovers automatically after fault condition is removed -30 ~ +70(Refer to "Derating Curve") -30 ~ +70(Refer to "Derating Curve")-30 ~ +70(Refer to "Derating Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH -40 ~ +85, 10 ~ 95% RH-40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 60) 0.03%/ (0 ~ 60)0.03%/ (0 ~ 60) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1,TUV EN60950-1,CCC GB4943 approved UL60950-1,TUV EN60950-1,CCC GB4943 approvedUL60950-1,TUV EN60950-1,CCC GB4943 approved I/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVACI/P-O/P:3.0KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RHI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25/ 70%RH Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1 Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria A Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria ACompliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV),criteria A 204K hrs min.MIL-HDBK-217F (25) 204K hrs min.MIL-HDBK-217F (25)204K hrs min.MIL-HDBK-217F (25) 210*62*31mm (L*W*H) 210*62*31mm (L*W*H)210*62*31mm (L*W*H) 0.52kg;20pcs/ 11.4kg/0.76CUFT 0.52kg;20pcs/ 11.4kg/0.76CUFT0.52kg;20pcs/ 11.4kg/0.76CUFT NOTE NOTENOTE 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature.1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.2. Ripple & noiseare measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : line regulation and load regulation. 3. Tolerance : line regulation and load regulation.3. Tolerance : line regulation and load regulation. 4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.4. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time. 5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time.5. Lengthof setup time is measured at cold first start.Turning ON/OFF the powersupply may leadto increase of the setup time. 6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com) 6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com)6. The powersupply is considered a component which will be installedinto a final equipment. All the EMC tests are been executed by mountingthe unit on a 450mm*450mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (as available on http://www.meanwell.com)File Name:HSP-200-SPEC2016-01-21 File Name:HSP-200-SPEC2016-01-21File Name:HSP-200-SPEC2016-01-21

Produktdokumente

Datenblatt

Technische Spezifikationen und Leistungsdaten

Benutzerhandbuch

Installations- und Betriebsanleitung

Top