| Parameter | Wert |
|---|---|
| Assembly procedure:- Strip wire 9.5 mm,- connect the stripped part of the wire through the locking sleeve (for wire diameter > 3.2 mm),- crimp wire (with protracted locking sleeve) with CK2.5...ED crimp contact,- lock the locking sleeve with the crimp contact together with the module's insulating body. | |
| Breite | 34.1 mm |
| Höhe | 61.3 mm |
| Länge | 29.3 mm |
| Serie | HC-M-HV |
| Allgemein | For HEAVYCON housing type B6 to B48, HC-M-B...MF-... hinged module carrier frame required, CK2,5-ED... imp contacts, crimp contacts not supplied as standard. |
| Anwendung | High-voltage |
| Produktart | Modular contact insert |
| Montagehinweis | To ensure correct use, installation in housing with IP54 protection or better is required |
| Bemessungsstrom | 16 A |
| Artikelüberarbeitung | 04 |
| Kontaktdurchmesser | 2.5 mm |
| Kontaktmaterial | Copper alloy |
| Kontaktnummerierung | I, II |
| Verbindungsprofil | 2 |
| Verschmutzungsgrad | 3 |
| Maßzeichnung | |
| Anzahl der Positionen | 2 |
| Bemessungsstoßspannung | 15 kV |
| Überspannungskategorie | III |
| Verbindungstechnologie | Crimp connection |
| Kontaktmaterialart | turned |
| Anzahl der Stromkontakte | 2 |
| Nennspannung (III/3) | 2900 V (Conductor-PE) |
| Normen/Vorschriften | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Mindestgehäusehöhe | 72 mm |
| Anzahl der Modulsteckplätze | 2 |
| Leiterquerschnitt | 0.5 mm² ... 4 mm² |
| Anzahl der Steuerkontakte | 0 |
| Kontaktträgermaterial | PC |
| Kontaktflächenmaterial | Ag (alternatively Au) |
| Einführ-/Entfernungszyklen | ≥ 500 |
| Anschlussquerschnitt AWG | 20 ... 12 |
| Umgebungstemperatur (Betrieb) | -40 °C ... 125 °C |
| Bemessungsspannung für Leistungskontakte | 2900/5000 V |
| Brennbarkeitsklasse gemäß UL 94 | V0 |
| Abisolierlänge des einzelnen Drahtes | 9.5 mm |
Technische Spezifikationen und Leistungsdaten