| Parameter | Wert |
|---|---|
| GTIN | 4055626112602 |
| Orderkey | 1417379 |
| Katalogseite | Page 563 (C-2-2017) |
| Verpackungseinheit | 2 pc |
| Ursprungsland | PL (Poland) |
| Zolltarifnummer | 85366990 |
| (Umgebungsbedingungen) | 16 mm (40 mm²) |
| Mindestbestellmenge | 2 pc |
| Kontaktmaterial (Allgemein) | Copper alloy |
| Nennstrom (Abmessungen) | 200 A |
| Breite (Wichtige Geschäftsdaten) | 34.2 mm |
| (Normen und Vorschriften) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Höhe (Wichtige Geschäftsdaten) | 60 mm |
| Länge (Wichtige kommerzielle Daten) | 29.4 mm |
| (Mechanische Eigenschaften) | The axial screw connection must be established using a 5 mm Allen key (for stranded conductors only) |
| Verbindungsprofil (Abmessungen) | 1 |
| Bemessungsstoßspannung (Abmessungen) | 8 kV |
| Anmerkung (Mechanische Eigenschaften) | For HEAVYCON HC-B6 to B48 housing (housing height: min. 72 mm), HC-M-B..-MF-... module carrier frame required, axial connection for 5 mm Allen key |
| Farbe (Mechanische Eigenschaften) | light gray |
| Kontaktträgermaterial (Allgemein) | PC |
| Kontaktflächenmaterial (Allgemein) | Ag |
| Nennspannung (III/3) (Abmessungen) | 1000 V |
| Baureihe (Mechanische Eigenschaften) | HC-M-HS |
| Gewicht pro Stück (ohne Verpackung) | 61.400 g |
| Kontaktdurchmesser (Umgebungsbedingungen) | 9.5 mm |
| Sechskantbuchse (Umgebungsbedingungen) | WAF 5 |
| China RoHS (Standards und Vorschriften) | Environmentally Friendly Use Period = 50 |
| Anzugsmoment (Umgebungsbedingungen) | 8 Nm (25 mm² ... 35 mm²) |
| Verbindung (Mechanische Eigenschaften) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| Kontaktart (Mechanische Eigenschaften) | turned |
| Minimale Gehäusehöhe (Umgebungsbedingungen) | 72 mm |
| Leiterquerschnitt (Umgebungsbedingungen) | 25 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Verbindungsmethode (Mechanische Eigenschaften) | Axial screw connection |
| Verschmutzungsgrad (Mechanische Eigenschaften) | 3 |
| Einführ-/Entfernungszyklen (Umgebungsbedingungen) | ≥ 500 |
| Anschlussquerschnitt AWG (Umgebungsbedingungen) | 10 ... |
| Überspannungskategorie (Mechanische Eigenschaften) | III |
| Montageanleitung (Mechanische Eigenschaften) | To ensure correct use, installation in housing with IP54 protection or better is required |
| Anzahl der Modulsteckplätze (Mechanische Eigenschaften) | 2 |
| Entflammbarkeitsklasse gemäß UL 94 (Materialdaten) | V0 |
| Drahtdurchmesser einschließlich Isolierung (Umgebungsbedingungen) | 12 mm (25 mm²) |
| Umgebungstemperatur (Betrieb) (Elektrische Eigenschaften) | -40 °C ... 125 °C |
| Abisolierlänge des einzelnen Drahtes (Umgebungsbedingungen) | 16 mm |
| Entflammbarkeitsklasse gemäß UL 94 (Mechanische Eigenschaften) | V0 |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung