| Parameter | Wert |
|---|---|
| Notiz | For HC-B10 housing, crimp contacts CK 2,5-ED (crimp contacts not included in scope of supply) |
| Typ | B10 |
| Verbindung | Connectors may only be inserted when there is no load/the power is switched off. Contact release by means of CK2,5-EWZ (Order No. 1662722) |
| Bemessungsstrom | 16 A |
| Kontaktmaterial | Copper alloy |
| Verschmutzungsgrad | 3 |
| Verbindungsmethode | Crimp connection |
| Anzahl der Positionen | 18+PE |
| Bemessungsstoßspannung | 6 kV |
| Überspannungskategorie | III |
| Montageanleitung | - Housing heights of h ≥ 72 mm are recommended when there is a high number of wires. |
| Nennspannung (III/3) | 500 V |
| Normen/Vorschriften | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Leiterquerschnitt | 0.5 mm² ... 4 mm² |
| Kontaktträgermaterial | PC |
| Kontaktflächenmaterial | Ag (alternatively Au) |
| Einführ-/Entfernungszyklen | ≥ 500 |
| Anschlussquerschnitt AWG | 20 ... 12 |
| Umgebungstemperatur (Betrieb) | -40 °C ... 125 °C (including heating up of contacts) |
| Anschluss gemäß Standard | IEC / EN |
| Brennbarkeitsklasse gemäß UL 94 | V0 |
| Abisolierlänge des einzelnen Drahtes | 7.5 mm |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung