| Parameter | Wert |
|---|---|
| PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) | |
| Notiz | For HEAVYCON ADVANCE and HEAVYCON housing of B6 type. Plug-in connections may only be operated only when there is no load/voltage. |
| Typ | B6 |
| Verbindung | Connectors may only be operated when there is no load/the power is switched off. Can be used for solid wires and stranded wires with ferrule. |
| Bemessungsstrom | 16 A |
| Kontaktmaterial | Copper alloy |
| Verschmutzungsgrad | 3 |
| Abstreiflänge | 8 mm ... 10 mm |
| Verbindungsmethode | Push-in connection |
| Anzahl der Positionen | 6+PE |
| Bemessungsstoßspannung | 6 kV |
| Überspannungskategorie | III |
| Montageanleitung | Coding also using the CP-HC (1686478) coding profiles. HC-B6../ HC-B10..for two coding profiles. HC-B16../ HC-B24..for four coding profiles. |
| Nennspannung (III/3) | 500 V |
| Normen/Vorschriften | PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2) |
| Leiterquerschnitt | 0.14 mm² ... 2.5 mm² |
| Kontaktträgermaterial | PA |
| Kontaktflächenmaterial | Ag/Sn (tarnish protection) |
| Einführ-/Entfernungszyklen | ≥ 500 |
| Anschlussquerschnitt AWG | 26 ... 14 |
| Umgebungstemperatur (Betrieb) | -40 °C ... 125 °C (including heating up of contacts) |
| Brennbarkeitsklasse gemäß UL 94 | V0 |
Technische Spezifikationen und Leistungsdaten