| Parameter | Wert |
|---|---|
| Artikel | Specifications |
| Kabel | 0.3 mm23-core oil resistant cabtyre cable, 1 m3.281 ftlong |
| Ausgabe | NPN open-collector transistor- Maximum sink current: 100 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Gewicht | Net weight : 45 g approx. |
| Details | GL-18H/18HL type |
| Produkt | Compact & Low Price Inductive Proximity Sensor |
| Material | Enclosure: Polyarylate |
| Hysterese | 15 % or less of operation distance (with standard sensing object) |
| Schutz | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
| Zubehör | - |
| Teilenummer | GL-18H |
| Produktname | Compact & Low Price Inductive Proximity Sensor GL |
| Produktnummer | GL-18H |
| Versorgungsspannung | 10 to 30 V DC Ripple P-P 10 % or less |
| Kabelverlängerung | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Umgebungsfeuchtigkeit | 45 to 85 % RH, Storage: 45 to 85 % RH |
| Stoßfestigkeit | 1,000 m/s2acceleration (100 G approx.) in X, Y and Z directions three times each |
| Umgebungstemperatur | -25 to +70 ℃-13 to +158℉,Storage: -25 to +70 ℃-13 to +158℉ |
| Aktueller Verbrauch | 10 mA or less |
| Betriebsanzeige | Red LED (lights up when the output is ON) |
| Stabiler Erfassungsbereich | 0 to 4 mm0 to 0.157 in(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Vibrationsfestigkeit | 10 to 55 Hz frequency, 1.5 mm0.059 indouble amplitude in X, Y and Z directions for two hours each |
| Isolationswiderstand | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Maximale Betriebsdistanz | 5 mm0.197 in± 10 %(Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
| Maximale Ansprechfrequenz | 1kHz |
| Ausgabe: Ausgabeoperation | Normally open |
| Standard-Erfassungsobjekt | Iron sheet 25 × 25 × t 1 mm0.984 × 0.984 × t 0.039 in |
| Spannungsfestigkeit | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Ausgabe: Nutzungskategorie | DC-12 or DC-13 |
| Einhaltung der CE-Kennzeichnungsrichtlinie | EMC Directive, RoHS Directive |
| Umweltbeständigkeit: Verschmutzungsgrad | 3 (Industrial environment) |
| Variation des Erfassungsbereichs: Spannungscharakteristik | Within ±2% for ±10 % fluctuation of the supply voltage |
| Variation des Erfassungsbereichs: Temperatureigenschaften | Over ambient temperature range -25 to +70 ℃-13 to +158℉: within ±10 % of sensing range at +20 ℃+68℉ |