| Parameter | Wert |
|---|---|
| 7 Nm (Support: EN 62444) | |
| Farbe | Brass color |
| Abgeschirmt | yes |
| Anwendung | EMC |
| halogenfrei | no |
| Hersteller | BIMED |
| Produktart | Cable screw gland |
| Gewindesteigung | 1.5 mm |
| Montagehinweis | Method 1Cut the outer sheath, but do not remove it. Feed the cable through the screw connection and then remove the outer sheath. Now pull the cable back until the connection is established between the cable shield and the contact spring.Method 2Push the braided shield back around 15 ... 20 mm over the outer sheath. Insert the cables into the screw connection until the connection is established between the cable shield and the contact spring. |
| Lochdurchmesser | 16.1 mm ... 16.2 mm |
| Artikelüberarbeitung | 00 |
| Anzugsmoment | 7 Nm (Union nut) |
| Maßzeichnung | |
| Schutzgrad | IP68 (5 bar, 30 minutes) |
| Dichtungsmaterial O-Ring | Perbunan |
| Schlüsselweite, Unterstützung | 20 mm |
| Konstruktion, Zugentlastung | A |
| Schlüsselweite, Überwurfmutter | 20 mm |
| Schutzart des Gehäuses (NEMA) | 4X |
| Außendurchmesser des Kabels | 5 mm ... 10 mm |
| Kategorie der Schockwirkung | 6 |
| Herstellerbezeichnung | BMEM-E1 |
| Dichtungsmaterial Kabeldichtung | CR |
| Winkelabmessung des Sechsecks | 22 mm |
| Material Kompressionsring | PA 6 |
| Gewindeanschlussseite | M16 x 1.5 |
| Werkstoff für Schraubverbindung | Brass, nickel-plated |
| Durchführung der Zugentlastung | A |
| Umgebungstemperatur (Betrieb) | -40 °C ... 100 °C (static) |
| Länge des Verbindungsgewindes | 7 mm |
| Kabeldurchmesser ohne Kabelmantel | 4 mm (Diameter of braided shield) |
| Klemmbereich der Zugentlastungsklemme | 6.00 mm ... 10.00 mm (for UL 514 B) |
Technische Spezifikationen und Leistungsdaten
Installations- und Betriebsanleitung